A new transurethral resection system: Operating in saline environment precludes obturator nerve reflexes

被引:30
作者
Shiozawa, H [1 ]
Aizawa, T
Ito, T
Miki, M
机构
[1] Tokyo Med Univ, Hachioji Med Ctr, Dept Urol, Tokyo, Japan
[2] Shinjuju Ishikawa Hosp, Dept Urol, Tokyo, Japan
关键词
urethra; surgical procedures; minimally invasive; obturator nerve; bladder;
D O I
10.1016/S0022-5347(05)64240-1
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We developed a transurethral resection system comprising a uniquely designed resectoscope and high frequency wave generator. The obturator nerve is free of electrical stimulation during transurethral resection since high frequency current is delivered via a resection loop to the sheath of the resectoscope in saline irrigation. Preclinical verification of the system was performed in an animal model to ensure its efficacy and operational safety. Materials and Methods: The swine bladder wall was transurethrally resected using the system in a saline environment. Results were subsequently compared with data on identical resection performed with the conventional system in sorbitol solution irrigation. Electrolyte contents were measured after resection for comparative evaluation with corresponding pre-resection data. Also, the depth of heat degeneration was measured in resected tissue. Results: No additional skills were required for bladder resection performed with the new system versus the conventional system. No lower limb adductor contraction was noted except minimal creeping during resection of a site close to the urethra. There were no apparent anomalies of blood electrolytes after transurethral resection. No difference was observed in the mean depth of heat degenerated tissues compared with the conventional system. Conclusions: The newly developed transurethral resection system was effective in a saline irrigated environment, which inhibited the obturator nerve reflex when applied in an animal model. This finding suggests promising potential for the system as a safe and cost-effective alternative compared with conventional transurethral resection.
引用
收藏
页码:2665 / 2667
页数:3
相关论文
共 10 条
[1]   Life-threatening haemorrhage following obturator artery injury during transurethral bladder surgery: a sequel of an unsuccessful obturator nerve block [J].
Akata, T ;
Murakami, J ;
Yoshinaga, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (07) :784-788
[2]   PREVENTION OF OBTURATOR NERVE-STIMULATION DURING TRANS-URETHRAL SURGERY [J].
AUGSPURGER, RR ;
DONOHUE, RE .
JOURNAL OF UROLOGY, 1980, 123 (02) :170-172
[3]   Electrovaporization of the prostate with the Gyrus device [J].
Botto, H ;
Lebret, T ;
Barré, P ;
Orsoni, JL ;
Hervé, JM ;
Lugagne, PM .
JOURNAL OF ENDOUROLOGY, 2001, 15 (03) :313-316
[4]   Early complications of endoscopic treatment for superficial bladder tumors [J].
Collado, A ;
Chéchile, GE ;
Salvador, J ;
Vicente, J .
JOURNAL OF UROLOGY, 2000, 164 (05) :1529-1532
[5]   Double-blind randomized study of symptoms associated with absorption of glycine 1.5% or mannitol 3% during transurethral resection of the prostate [J].
Hahn, RG ;
Sandfeldt, L ;
Nyman, CR .
JOURNAL OF UROLOGY, 1998, 160 (02) :397-401
[6]  
Hradec E, 1983, Int Urol Nephrol, V15, P149
[7]   A comparison of 1.5% glycine and 2.7% sorbitol-0.5% mannitol irrigants during transurethral prostate resection [J].
Inman, RD ;
Hussain, Z ;
Elves, AWS ;
Hallworth, MJ ;
Jones, PW ;
Coppinger, SWV .
JOURNAL OF UROLOGY, 2001, 166 (06) :2216-2220
[8]   Long-term consequences from bladder perforation and/or violation in the presence of transitional cell carcinoma: Results of a small series and a review of the literature [J].
Mydlo, JH ;
Weinstein, R ;
Shah, S ;
Solliday, M ;
Macchia, RJ .
JOURNAL OF UROLOGY, 1999, 161 (04) :1128-1132
[9]   ELECTROSURGERY PRINCIPLES - CUTTING CURRENT AND CUTANEOUS SURGERY .1. [J].
SEBBEN, JE .
JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1988, 14 (01) :29-31
[10]   ACCURATE OBTURATOR NERVE BLOCK IN TRANS-URETHRAL SURGERY [J].
YAZAKI, T ;
ISHIKAWA, H ;
KANOH, S ;
KOISO, K .
UROLOGY, 1985, 26 (06) :588-589