Reducing metal artifacts in cone-beam CT images by preprocessing projection data

被引:174
作者
Zhang, Yongbin
Zhang, Lifei
Zhu, Ronald
Lee, Andrew K.
Chambers, Mark
Dong, Lei
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Dent Oncol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 67卷 / 03期
关键词
metal artifacts; cone-beam CT; image-guided radiotherapy; image reconstruction; image-guided radiation therapy;
D O I
10.1016/j.ijrobp.2006.09.045
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Computed tomography (CT) streak artifacts caused by metallic implants remain a challenge for the automatic processing of image data. The impact of metal artifacts in the soft-tissue region is magnified in cone-beam CT (CBCT), because the soft-tissue contrast is usually lower in CBCT images. The goal of this study was to develop an effective offline processing technique to minimize the effect. Methods and Materials: The geometry calibration cue of the CBCT system was used to track the position of the met object in projection views. The three-dimensional (3D) representation of the object can be established from only two user-selected viewing angles. The position of the shadowed region in other views can be tracked by projecting the 3D coordinates of the object. Automatic image segmentation was used followed by a Laplacian diffusion method to replace the pixels inside the metal object with the boundary pixels. The modified projection data were then used to reconstruct a new CBCT image. The procedure was tested in phantoms, prostate cancer patients with implanted gold markers and metal prosthesis, and a head-and-neck patient with dental amalgam in the teeth. Results: Both phantom and patient studies demonstrated that the procedure was able to minimize the metal artifacts. Soft-tissue visibility was improved near or away from the metal object. The processing time was 1-2 s per projection. Conclusion: We have implemented an effective metal artifact-suppressing algorithm to improve the quality of CBCT images. (c) 2007 Elsevier Inc.
引用
收藏
页码:924 / 932
页数:9
相关论文
共 41 条
[1]   Correction of streaking artifacts in CT images and its influence on Monte Carlo dose calculations [J].
Bazalova, M. ;
Palefsky, S. ;
Beaulieu, L. ;
Verhaegen, F. .
MEDICAL PHYSICS, 2006, 33 (06) :2158-2159
[2]   A novel method for reducing high attenuation object artifacts in CT reconstructions [J].
Chen, LG ;
Liang, Y ;
Sandison, GA ;
Rydberg, J .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :841-850
[3]   Automatic registration of the prostate for computed-tomography-guided radiotherapy [J].
Court, LE ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (10) :2750-2757
[4]   Cone-beam CT for image-guided head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. ;
Siewerdsen, J. ;
Moseley, D. ;
Jaffray, D. .
MEDICAL PHYSICS, 2006, 33 (06) :2229-2229
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   Breath hold cone beam CT for image guided stereotactic radiotherapy for liver cancer [J].
Hawkins, MA ;
Brock, K ;
Eccles, C ;
Moseley, D ;
Jaffray, D ;
Dawson, LA .
RADIOTHERAPY AND ONCOLOGY, 2006, 78 :S80-S80
[7]   Volumetric image-guidance for therapy: Performance, quality and opportunity [J].
Jaffray, D .
MEDICAL PHYSICS, 2005, 32 (06) :2067-2067
[8]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[9]   A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine [J].
Joseph, PM ;
Ruth, C .
MEDICAL PHYSICS, 1997, 24 (10) :1629-1634
[10]   REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577