Flat-panel cone-beam computed tomography for image-guided radiation therapy

被引:1182
作者
Jaffray, DA [1 ]
Siewerdsen, JH [1 ]
Wong, JW [1 ]
Martinez, AA [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 53卷 / 05期
关键词
cone-beam computed tomography; linear accelerator; image guidance; flat-panel detectors;
D O I
10.1016/S0360-3016(02)02884-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: Geometric uncertainties in the process of radiation planning and delivery constrain dose escalation and induce normal tissue complications. An imaging system has been developed to generate high-resolution, soft-tissue images of the patient at the time of treatment for the purpose of guiding therapy and reducing such uncertainties. The performance of the imaging system is evaluated and the application to image-guided radiation therapy is discussed. Methods and Materials: A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography (CT) has been integrated with a medical linear accelerator. Kilovoltage X-rays are generated by a conventional X-ray tube mounted on a retractable arm at 90degrees to the treatment source. A 41 X 41 cm(2) flat-panel X-ray detector is mounted opposite the kV tube. The entire imaging system operates under computer control, with a single application providing calibration, image acquisition, processing, and cone-beam CT reconstruction. Cone-beam CT imaging involves acquiring multiple kV radiographs as the gantry rotates through 360degrees of rotation. A filtered back-projection algorithm is employed to reconstruct the volumetric images. Geometric nonidealities in the rotation of the gantry system are measured and corrected during reconstruction. Qualitative evaluation of imaging performance is performed using an anthropomorphic head phantom and a coronal contrast phantom. The influence of geometric nonidealities is examined. Results: Images of the head phantom were acquired and illustrate the submillimeter spatial resolution that is achieved with the cone-beam approach. High-resolution sagittal and coronal views demonstrate nearly isotropic spatial resolution. Flex corrections on the order of 0.2 cm were required to compensate gravity-induced flex in the support arms of the source and detector, as well as slight axial movements of the entire gantry structure. Images reconstructed without flex correction suffered from loss of detail, misregistration, and streak artifacts. Reconstructions of the contrast phantom demonstrate the soft-tissue imaging capability of the system. A contrast of 47 Hounsfield units was easily detected in a 0.1-cm-thick reconstruction for an imaging exposure of 1.2 R (in-air, in absence of phantom). The comparison with a conventional CT scan of the phantom further demonstrates the spatial resolution advantages of the cone-beam CT approach. Conclusions: A kV cone-beam CT imaging system based on a large-area, flat-panel detector has been successfully adapted to a medical linear accelerator. The system is capable of producing images of soft tissue with excellent spatial resolution at acceptable imaging doses. Integration of this technology with the medical accelerator will result in an ideal platform for high-precision, image-guided radiation therapy. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1337 / 1349
页数:13
相关论文
共 51 条
[1]
Variation in prostate position relative to adjacent bony anatomy [J].
Althof, VGM ;
Hoekstra, CJM ;
Loo, HJT .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :709-715
[2]
Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[3]
ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[4]
MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[5]
RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS [J].
BRAHME, A ;
LIND, B ;
NAFSTADIUS, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :95-101
[6]
CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[7]
PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[8]
Characterization of a fluoroscopic imaging system for kV and MV radiography [J].
Drake, DG ;
Jaffray, DA ;
Wong, JW .
MEDICAL PHYSICS, 2000, 27 (05) :898-905
[9]
Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities [J].
Fahrig, R ;
Holdsworth, DW .
MEDICAL PHYSICS, 2000, 27 (01) :30-38
[10]
PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619