Large volume cold on-column injection for gas chromatography-negative chemical ionization-mass spectrometry analysis of selected pesticides in air samples

被引:32
作者
Bailey, Renata [1 ]
Belzer, Wayne
机构
[1] Univ Regina, Dept Chem, Regina, SK S4S 0A2, Canada
[2] Environm Canada, Aquat & Atmosper Sci Div, Vancouver, BC V6C 3S5, Canada
关键词
cold on-column; large volume injection; gas chromatography-mass spectrometry; pesticides; fungicides;
D O I
10.1021/jf062972h
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A new gas chromatographic method is described for the analysis of fungicides captan, captafol, and folpet from organic extracts of air samples using large volume injection (LVI) via a cold on-column (COC) inlet coupled with gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS). Although standard split/splitless injection due to high injection port temperatures (> 225 degrees C) have been shown to degrade these thermally labile fungicides, COC injection minimizes degradation. Insecticides such as chlorpyrifos and diazinon were also examined to show added selectivity. By using a solvent vapor exit with the COC inlet, injection volumes of 10-100 mu L can be made to lower detection levels. GC-NCI-MS was compared to GC-electron impact ionization-mass spectrometry for each pesticide using LVI-COC injections and was found to be 2-80 times more sensitive, depending on the pesticide. Method detection limit (MDL) values with 100 mu L injections were 2.5 mu g L-1 for captan, folpet, and diazinon, 5.0 mu g L-1 captafol, and 1.0 mu g L-1 for chlorpyrifos, with the normal working range examined for sample analysis from MDL to 100 mu g L-1. Detection of all pesticides except captafol, used only in the United States but not Canada, was demonstrated from air samples taken from Abbotsford, British Columbia, Canada.
引用
收藏
页码:1150 / 1155
页数:6
相关论文
共 37 条
[31]   Multiresidue determination of pesticides in malt beverages by capillary gas chromatography with mass spectrometry and selected ion monitoring [J].
Wong, JW ;
Webster, MG ;
Bezabeh, DW ;
Hengel, MJ ;
Ngim, KK ;
Krynitsky, AJ ;
Ebeler, SE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (21) :6361-6372
[32]   Multiresidue pesticide analysis in wines by solid-phase extraction and capillary gas chromatography-mass spectrometric detection with selective ion monitoring [J].
Wong, JW ;
Webster, MG ;
Halverson, CA ;
Hengel, MJ ;
Ngim, KK ;
Ebeler, SE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (05) :1148-1161
[33]   Performance of programmed temperature vaporizer, pulsed splitless and on-column injection techniques in analysis of pesticide residues in plant matrices [J].
Zrostíková, J ;
Hajslová, J ;
Godula, M ;
Mastovská, K .
JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) :73-86
[34]  
Zrostlíková J, 2002, J SEP SCI, V25, P527, DOI 10.1002/1615-9314(20020601)25:8&lt
[35]  
527::AID-JSSC527&gt
[36]  
3.0.CO
[37]  
2-