MR microscopy of micron scale structures

被引:12
作者
Lee, Seung-Cheol [1 ,2 ]
Kim, Kiseong [1 ]
Kim, Junghyun [1 ]
Yi, Jeong Han [3 ]
Lee, Soonchil [1 ]
Cheong, Chaejoon [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Phys, Taejon 305701, South Korea
[2] Korea Basic Sci Inst, Magnet Resonance Team, Chungbuk 363883, South Korea
[3] Konkuk Univ, Dept Biomed Engn, Chungbuk 380701, South Korea
关键词
NMR; Microscopy; Silicon; Micron; Resolution; MRI; MAGNETIC-RESONANCE MICROSCOPY; NMR MICROSCOPY; RESOLUTION;
D O I
10.1016/j.mri.2009.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) microscopy of up to 1-5-mu m resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e. g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In this study, we fabricated structures having a few micron widths on a silicon wafer and imaged them using our 1-mu m-resolution MR microscopy at 14.1 T. Micron scale width structures were, for the first time, resolved by MR microscopy. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:828 / 833
页数:6
相关论文
共 20 条
[1]   MR microscopy and high resolution'small animal MRI: applications in neuroscience research [J].
Benveniste, H ;
Blackband, S .
PROGRESS IN NEUROBIOLOGY, 2002, 67 (05) :393-420
[2]  
Blumer P., 1998, SPATIALLY RESOLVED M
[3]  
Callaghan P. T., 1991, Principles of Nuclear Magnetic Resonance Microscopy
[4]   SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :304-318
[5]   Magnetic resonance imaging of biological cells [J].
Ciobanu, L ;
Webb, AG ;
Pennington, CH .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2003, 42 (3-4) :69-93
[6]   3D MR microscopy with resolution 3.7 μm by 3.3 μm by 3.3 μm [J].
Ciobanu, L ;
Seeber, DA ;
Pennington, CH .
JOURNAL OF MAGNETIC RESONANCE, 2002, 158 (1-2) :178-182
[7]   Limits to magnetic resonance microscopy [J].
Glover, P ;
Mansfield, P .
REPORTS ON PROGRESS IN PHYSICS, 2002, 65 (10) :1489-1511
[8]   A FAST, ITERATIVE, PARTIAL-FOURIER TECHNIQUE CAPABLE OF LOCAL PHASE RECOVERY [J].
HAACKE, EM ;
LINDSKOG, ED ;
LIN, W .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01) :126-145
[9]   A MODIFIED IMAGING SEQUENCE FOR ACCURATE T-2 MEASUREMENTS USING NMR MICROSCOPY [J].
HSU, EW ;
SCHOENIGER, JS ;
BOWTELL, R ;
AIKEN, NR ;
HORSMAN, A ;
BLACKBAND, SJ .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (01) :66-69
[10]   MODIFIED PULSED GRADIENT TECHNIQUE FOR MEASURING DIFFUSION IN THE PRESENCE OF LARGE BACKGROUND GRADIENTS [J].
KARLICEK, RF ;
LOWE, IJ .
JOURNAL OF MAGNETIC RESONANCE, 1980, 37 (01) :75-91