The impact of lesion length and vessel size on outcomes after sirolimus-eluting stent implantation for in-stent restenosis

被引:19
作者
Habara, S. [1 ]
Mitsudo, K. [1 ]
Goto, T. [1 ]
Kadota, K. [1 ]
Fujii, S. [1 ]
Yamamoto, H. [1 ]
Kato, H. [1 ]
Takenaka, S. [1 ]
Fuku, Y. [1 ]
Hosogi, S. [1 ]
Hirono, A. [1 ]
Yamamoto, K. [1 ]
Tanaka, H. [1 ]
Hasegawa, D. [1 ]
Nakamura, Y. [1 ]
Tasaka, H. [1 ]
Otsuru, S. [1 ]
Okamoto, Y. [1 ]
Yamada, C. [1 ]
Miyamoto, M. [1 ]
Inoue, K. [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiol, Kurashiki, Okayama 7108602, Japan
关键词
D O I
10.1136/hrt.2007.128595
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We evaluated the predictors of recurrent restenosis and the impact of lesion length and vessel size on outcomes in patients treated with routine sirolimus-eluting stent (SES) implantation for in-stent restenosis (ISR) of bare-metal stent (BMS). Methods: In this study, 250 consecutive patients with 275 lesions after SES implantation for ISR of BMS were enrolled. Follow-up angiogram was obtained in 239 patients with 258 lesions eight months after implantation (follow-up rate: 95.6%). We compared characteristics of patients and lesions between the two groups (the recurrent restenosis group and the no-restenosis group). Results: Recurrent restenosis was angiographically documented in 43 lesions (16.7%). Recurrent restenosis was found in 30.4% with small vessel lesions (reference diameter of less than 2.5 mm, 92 lesions) and 23% with the diffuse type lesions (106 lesions). Seventy-two per cent of patients had a focal pattern of recurrent restenosis. Previously recurrent ISR lesions (odds ratio (OR) 1.94, 95% confidence interval (CI) 0.94 to 4.06, p = 0.05), reference diameter of less than 2.5 mm (OR 2.41, CI 1.05 to 5.41, p = 0.03), diffuse type restenosis (OR 4.48, CI 2.12 to 9.94, p = 0.0001) and dialysis patients (OR 4.72, CI 1.42 to 15.7, p = 0.01) were independent predictors of recurrent restenosis. Conclusions: Small vessels, diffuse type restenosis and dialysis patients were still the predictors of recurrent restenosis in patients treated with SES for ISR of BMS.
引用
收藏
页码:1162 / 1165
页数:4
相关论文
共 16 条
[1]   A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis -: Results of the restenosis intrastent:: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial [J].
Alfonso, Fernando ;
Perez-Vizcayno, Maria-Jose ;
Hernandez, Rosana ;
Bethencourt, Armando ;
Marti, Vicens ;
Lopez-Minguez, Jose R. ;
Angel, Juan ;
Mantilla, Ramon ;
Moris, Cesar ;
Cequier, Angel ;
Sabate, Manel ;
Escaned, Javier ;
Moreno, Raul ;
Bañuelos, Camino ;
Suarez, Alfonso ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2152-2160
[2]   Impact of end-stage renal disease on clinical and angiographic outcomes after coronary stenting [J].
Azar, RR ;
Prpic, R ;
Ho, KKL ;
Kiernan, FJ ;
Shubrooks, SJ ;
Baim, DS ;
Popma, JJ ;
Kuntz, RE ;
Cohen, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (05) :485-489
[3]   Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience [J].
Degertekin, M ;
Regar, E ;
Tanabe, K ;
Smits, PC ;
van der Giessen, WJ ;
Carlier, SG ;
de Feyter, P ;
Vos, J ;
Foley, DP ;
Ligthart, JMR ;
Popma, JJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) :184-189
[4]   Effectiveness of drug-eluting stents in patients with bare-metal in-stent restenosis -: Meta-analysis of randomized trials [J].
Dibra, Alban ;
Kastrati, Adrian ;
Alfonso, Fernando ;
Seyfarth, Melchior ;
Perez-Vizcayno, Maria-Jose ;
Mehilli, Julinda ;
Schomig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (05) :616-623
[5]   Vessel size and outcome after coronary drug-eluting stent placement:: Results from a large cohort of patients treated with sirolimus- or paclitaxel-eluting stents [J].
Elezi, Shpend ;
Dibra, Alban ;
Mehilli, Julinda ;
Pache, Juergen ;
Wessely, Rainer ;
Schoemig, Albert ;
Kastrati, Adnan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) :1304-1309
[6]   Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis [J].
Fujii, K ;
Mintz, GS ;
Kobayashi, Y ;
Carlier, SG ;
Takebayashi, H ;
Yasuda, T ;
Moussa, I ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Reyes, A ;
Kreps, E ;
Collins, M ;
Colombo, A ;
Stone, GW ;
Teirstein, PS ;
Leon, MB ;
Moses, JW .
CIRCULATION, 2004, 109 (09) :1085-1088
[7]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[8]   Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents - The SISR randomized trial [J].
Holmes, DR ;
Teirstein, P ;
Satler, L ;
Sketch, M ;
O'Malley, J ;
Popma, JJ ;
Kuntz, RE ;
Fitzgerald, PJ ;
Wang, H ;
Caramanica, E ;
Cohen, SA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (11) :1264-1273
[9]   Analysis of 1-year clinical outcomes in the SIRIUS trial - A randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis [J].
Holmes, DR ;
Leon, MB ;
Moses, JW ;
Popma, JJ ;
Cutlip, D ;
Fitzgerald, PJ ;
Brown, C ;
Fischell, T ;
Wong, SC ;
Midei, M ;
Snead, D ;
Kuntz, RE .
CIRCULATION, 2004, 109 (05) :634-640
[10]   Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis -: A randomized controlled trial [J].
Kastrati, A ;
Mehilli, J ;
von Beckerath, N ;
Dibra, A ;
Hausleiter, J ;
Pache, J ;
Schühlen, H ;
Schmitt, C ;
Dirschinger, J ;
Schömig, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (02) :165-171