Informed RESTORE: A method for robust estimation of diffusion tensor from low redundancy datasets in the presence of physiological noise artifacts

被引:91
作者
Chang, Lin-Ching [1 ]
Walker, Lindsay [2 ,3 ]
Pierpaoli, Carlo [3 ]
机构
[1] Catholic Univ Amer, Dept Elect Engn & Comp Sci, Washington, DC 20064 USA
[2] Uniformed Serv Univ Hlth Sci, Ctr Neurosci & Regenerat Med, Bethesda, MD 20814 USA
[3] NICHHD, NIH, Bethesda, MD 20892 USA
基金
美国国家科学基金会;
关键词
RESTORE; diffusion tensor; robust estimation; artifact; outlier; trace; fractional anisotropy; DISTORTION CORRECTION; B-MATRIX; SCHEMES; MOTION; TISSUES;
D O I
10.1002/mrm.24173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Physiological noise artifacts, especially those originating from cardiac pulsation and subject motion, are common in clinical Diffusion tensor-MRI acquisitions. Previous works show that signal perturbations produced by artifacts can be severe and neglecting to account for their contribution can result in erroneous diffusion tensor values. The Robust Estimation of Tensors by Outlier Rejection (RESTORE) method has been shown to be an effective strategy for improving tensor estimation on a voxel-by-voxel basis in the presence of artifactual data points in diffusion-weighted images. In this article, we address potential instabilities that may arise when using RESTORE and propose practical constraints to improve its usability. Moreover, we introduce a method, called informed RESTORE designed to remove physiological noise artifacts in datasets acquired with low redundancy (less than 3040 diffusion-weighted image volumes)a condition in which the original RESTORE algorithm may converge to an incorrect solution. This new method is based on the notion that physiological noise is more likely to result in signal dropouts than signal increases. Results from both Monte Carlo simulation and clinical diffusion data indicate that informed RESTORE performs very well in removing physiological noise artifacts for low redundancy diffusion-weighted image datasets. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1654 / 1663
页数:10
相关论文
共 37 条
[1]
Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[2]
Barnett V., 1985, OUTLIERS STAT DATA, V2nd
[3]
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[4]
ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[5]
Bevington P.R, 1969, Data Reduction and Error Analysis for the Physical Sciences
[6]
RESTORE: Robust estimation of tensors by outlier rejection [J].
Chang, LC ;
Jones, DK ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1088-1095
[7]
Chang LC, 2009, ISMRM 17 ANN M EXH H, P3557
[8]
Variance of estimated DTI-derived parameters via first-order perturbation methods [J].
Chang, Lin-Ching ;
Koay, Cheng Guan ;
Pierpaoli, Carlo ;
Basser, Peter J. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :141-149
[9]
Cormen TH., 2009, Introduction to Algorithms, V3
[10]
A Method to Assess Spatially Variant Noise in Dynamic MR Image Series [J].
Ding, Yu ;
Chung, Yiu-Cho ;
Simonetti, Orlando P. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :782-789