Biomechanics of Lumbar Cortical Screw-Rod Fixation Versus Pedicle Screw-Rod Fixation With and Without Interbody Support

被引:189
作者
Perez-Orribo, Luis [1 ]
Kalb, Samuel [2 ]
Reyes, Phillip M. [1 ]
Chang, Steve W. [1 ,2 ]
Crawford, Neil R. [1 ]
机构
[1] St Josephs Hosp, Spinal Biomech Lab, Dept Neurosurg Res, Phoenix, AZ 85013 USA
[2] St Josephs Hosp, Div Neurol Surg, Barrow Neurol Inst, Phoenix, AZ 85013 USA
关键词
cortical screw; pedicle screw; lumbar biomechanics; lateral interbody fixation; transforaminal lumbar interbody fixation; FUSION; DEVICES;
D O I
10.1097/BRS.0b013e318279a95e
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design. Seven different combinations of posterior screw fixation, with or without interbody support, were compared in vitro using nondestructive flexibility tests. Objective. To study the biomechanical behavior of a new cortical screw (CS) fixation construct relative to the traditional pedicle screw (PS) construct. Summary of Background Data. The CS is an alternative to the PS for posterior fixation of the lumbar spine. The CS trajectory is more sagittally and cranially oriented than the PS, being anchored in the pars interarticularis. Like PS fixation, CS fixation uses interconnecting rods fastened with top-locking connectors. Stability after bilateral CS fixation was compared with stability after bilateral PS fixation in the setting of intact disc and with direct lateral interbody fixation (DLIF) or transforaminal lateral interbody fixation (TLIF) support. Methods. Standard nondestructive flexibility tests were performed in cadaveric lumbar specimens, allowing non-paired comparisons of specific conditions from 28 specimens (4 groups of 7) within a larger experiment of multiple hardware configurations. Condition tested and group from which results originated were as follows: (1) intact (all groups); (2) with L3-L4 bilateral PS-rods (group 1); (3) with bilateral CS-rods (group 2); (4) with DLIF (group 3); (5) with DLIF + CS-rods (group 4); (6) with DLIF + PS-rods (group 3); (7) with TLIF + CS-rods (group 2), and (8) with TLIF + PS-rods (group 2). To assess spinal stability, the mean range of motion, lax zone, and stiff zone at L3-L4 were compared during flexion-extension, lateral bending, and axial rotation. Results. With intact disc, stability was equivalent after PS-rod and CS-rod fixation, except that PS-rod fixation was stiffer during axial rotation. With DLIF support, there was no significant difference in stability between PS-rod and CS-rod fixation. With TLIF support, PS-rod fixation was stiffer than CS-rod fixation during lateral bending. Conclusion. Bilateral CS-rod fixation provided about the same stability in cadaveric specimens as PS-rod fixation regardless of the presence of interbody, TLIF, or DLIF support.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 20 条
[1]
Barber JW, 1998, J SPINAL DISORD, V11, P215
[2]
Minimally invasive anterolateral approaches for the treatment of back pain and adult degenerative deformity [J].
Benglis, David M. ;
Elhammady, Mohamed Samy ;
Levi, Allan D. ;
Vanni, Steven .
NEUROSURGERY, 2008, 63 (03) :A191-A196
[3]
Pedicle screw fixation in spinal disorders: A European view [J].
Boos N. ;
Webb J.K. .
European Spine Journal, 1997, 6 (1) :2-18
[4]
Brodke D S, 2001, Spine J, V1, P373, DOI 10.1016/S1529-9430(01)00116-4
[5]
The biomechanics of pedicle screw-based instrumentation [J].
Cho, W. ;
Cho, S. K. ;
Wu, C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1061-1065
[6]
A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[7]
AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[8]
Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[9]
Crawford NR, 1998, J SPINAL DISORD, V11, P416
[10]
CORRELATIONS BETWEEN SCREW HOLE PREPARATION, TORQUE OF INSERTION, AND PULLOUT STRENGTH FOR SPINAL SCREWS [J].
DAFTARI, TK ;
HORTON, WC ;
HUTTON, WC .
JOURNAL OF SPINAL DISORDERS, 1994, 7 (02) :139-145