The making of frozen-hydrated, vitreous lamellas from cells for cryo-electron microscopy

被引:69
作者
Hayles, Michael F. [1 ]
de Winter, D. A. Matthijs [2 ]
Schneijdenberg, Chris T. W. M. [2 ]
Meeldijk, Johannes D. [2 ,3 ]
Luecken, Uwe [1 ]
Persoon, Hans [1 ]
de Water, Jeroen [1 ]
de Jong, Frank [1 ]
Humbel, Bruno M. [2 ,4 ]
Verkleij, Arie J. [2 ]
机构
[1] FEI Co, NL-5600 KA Eindhoven, Netherlands
[2] Univ Utrecht, Fac Sci, NL-3584 CH Utrecht, Netherlands
[3] Univ Utrecht, Fac Sci, Debye Inst Nanomat Sci, NL-3584 CH Utrecht, Netherlands
[4] Univ Lausanne, Fac Biol & Med, Ctr Electron Microscopy, CH-1005 Lausanne, Switzerland
关键词
FIB-SEM; Cryo-TEM; CEMOVIS; Cryo-fixation; Yeast; Cryo-section; Cryo-lamella; FOCUSED-ION-BEAM; BIOLOGICAL CELLS; YEAST; TISSUE; ULTRAMICROTOMY; TOMOGRAPHY; ARTIFACTS; MEMBRANE; SECTIONS; WATER;
D O I
10.1016/j.jsb.2010.07.004
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There has been a long standing desire to produce thick (up to 500 nm) cryo-sections of fully hydrated cells and tissue for high-resolution analysis in their natural state by cryo-transmission electron microscopy. Here, we present a method that can successfully produce sections (lamellas in FIB-SEM terminology) of fully hydrated, unstained cells from high-pressure frozen samples by focused ion beam (FIB) milling. The samples are therefore placed in thin copper tubes and vitrified by high-pressure freezing. For transfer, handling and subsequent milling, the tubes are placed in a novel connective device (ferrule) that protects the sample from devitrification and contamination and passes through all operation steps. A piezo driven sample positioning stage (cryo-nano-bench, CNB) with three degrees of freedom was additionally developed to enable accurate milling of frozen-hydrated lamellas. With the CNB, high-pressure frozen samples can be milled to produce either thin lamellas (<100 nm), for direct imaging by high-resolution cryo-TEM or thicker lamellas (300-500 nm) for cryo-electron tomography. The sample remains vitreous throughout the process by using the presented tools and methods. The results are an important step towards investigating larger cells and even tissue in there natural state which in the end will enable us to gain better insights into cellular processes. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:180 / 190
页数:11
相关论文
共 36 条
[11]  
Giannuzzi L. A., 2005, INTRO FOCUSED BEAMS
[12]   DECORATION OF SPECIFIC SITES ON FREEZE-FRACTURED MEMBRANES [J].
GROSS, H ;
KUEBLER, O ;
BAS, E ;
MOOR, H .
JOURNAL OF CELL BIOLOGY, 1978, 79 (03) :646-656
[13]  
Hayat MA, 2000, PRINCIPLES AND TECHNIQUES OF ELECTRON MICROSCOPY: BIOLOGICAL APPLICATIONS, FOURTH EDITION, P1
[14]   A technique for improved focused ion beam milling of cryo-prepared life science specimens [J].
Hayles, M. F. ;
Stokes, D. J. ;
Phifer, D. ;
Findlay, K. C. .
JOURNAL OF MICROSCOPY, 2007, 226 (03) :263-269
[15]   STRUCTURE OF PURPLE MEMBRANE FROM HALOBACTERIUM-HALOBIUM [J].
HENDERSON, R ;
UNWIN, PNT .
BIOPHYSICS OF STRUCTURE AND MECHANISM, 1977, 3 (02) :121-121
[16]   Towards high-resolution three-dimensional imaging of native mammalian tissue: Electron tomography of frozen-hydrated rat liver sections [J].
Hsieh, CE ;
Leith, A ;
Mannella, CA ;
Frank, J ;
Marko, M .
JOURNAL OF STRUCTURAL BIOLOGY, 2006, 153 (01) :1-13
[17]   Electron tomographic analysis of frozen-hydrated tissue sections [J].
Hsieh, CE ;
Marko, M ;
Frank, J ;
Mannella, CA .
JOURNAL OF STRUCTURAL BIOLOGY, 2002, 138 (1-2) :63-73
[18]   ARTIFACTS AND MORPHOLOGICAL-CHANGES DURING CHEMICAL FIXATION [J].
KELLENBERGER, E ;
JOHANSEN, R ;
MAEDER, M ;
BOHRMANN, B ;
STAUFFER, E ;
VILLIGER, W .
JOURNAL OF MICROSCOPY, 1992, 168 :181-201
[19]   Serial section scanning electron microscopy of adult brain tissue using focused ion beam milling [J].
Knott, Graham ;
Marchman, Herschel ;
Wall, David ;
Lich, Ben .
JOURNAL OF NEUROSCIENCE, 2008, 28 (12) :2959-2964
[20]   Focused ion beam milling of vitreous water: prospects for an alternative to cryo-ultramicrotomy of frozen-hydrated biological samples [J].
Marko, M ;
Hsieh, C ;
Moberlychan, W ;
Mannella, CA ;
Frank, J .