New circulating-water devices warm more quickly than forced-air in volunteers

被引:20
作者
Wadhwa, Anupama
Komatsu, Ryu
Orhan-Sungur, Mukadder
Barnes, Pamela
In, JangHyeok
Sessler, Daniel I.
Lenhardt, Rainer
机构
[1] Univ Louisville Hosp, Dept Anesthesiol & Perioperat Med, Louisville, KY 40202 USA
[2] Univ Louisville, Outcomes Res Inst, Louisville, KY USA
[3] Univ Chicago, Dept Anesthesiol, Chicago, IL 60637 USA
[4] Cleveland Clin, Dept Outcomes Res, Cleveland, OH USA
[5] Univ Louisville, Neurosci Intens Care Unit, Louisville, KY 40292 USA
关键词
D O I
10.1213/01.ane.0000289534.65690.ce
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Newer circulating-water systems supply more heat than forced-air, mainly because the heat capacity of water is much greater than for that of dry warm air and, in part, because they provide posterior as well as anterior heating. Several heating systems are available, but three major ones have yet to be compared directly. We therefore compared two circulating-water systems with a forced-air system during simulation of upper abdominal or chest surgery in vounteers. METHODS: Seven healthy volunteers participated on three separate study days. Each day, they were anesthetized and cooled to a core temperature near 34 degrees C, which was maintained for 45-60 min. They were then rewarmed with one of three warming systems until distal esophageal core temperature reached 36 degrees C or anesthesia had lasted 8 h. The warming systems were 1) energy transfer pads (two split torso pads and two universal pads; Kimberly Clark, Roswell, GA); 2) circulating-water garment (Allon MTRE 3365 for cardiac surgery, Akiva, Israel); and 3) lower body forced-air warming (Bair Hugger #525, #750 blower, Eden Prairie, MN). Data are presented as mean +/- SD; P < 0.05 was statistically significant. RESULTS: The rate of increase of core temperature from 34 degrees C to 36 degrees C was 1.2 degrees C +/- 0.2 degrees C/h with the Kimberly Clark system, 0.9 degrees C +/- 0.2 degrees C/h with the Allon system, and 0.6 degrees C +/- 0.1 degrees C/h with the Bair Hugger (P = 0.002). CONCLUSIONS: The warming rate with the Kimberly Clark system was 25% faster than with the Allon system and twice as fast as with the Bair Hugger. Both circulating-water systems thus warmed hypothermic volunteers in significantly less time than the forced-air system.
引用
收藏
页码:1681 / 1687
页数:7
相关论文
共 38 条
[1]   THE POSTANESTHESIA RECOVERY SCORE REVISITED [J].
ALDRETE, JA .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (01) :89-91
[2]   PREGNANCY TESTING IN ADOLESCENT PRESURGICAL PATIENTS [J].
AZZAM, FJ ;
KROCK, JL .
ANESTHESIA AND ANALGESIA, 1995, 81 (03) :661-661
[3]  
Bissonnette B, 2002, CAN J ANAESTH, V49, P270, DOI 10.1007/BF03020526
[4]   Human calorimetry II. The average temperature of the tissues of the body [J].
Burton, AC .
JOURNAL OF NUTRITION, 1935, 9 (03) :261-280
[5]   INVESTIGATION OF THE RELATIONSHIP BETWEEN HEAT-LOSS AND NITROGEN-EXCRETION IN ELDERLY PATIENTS UNDERGOING MAJOR ABDOMINAL-SURGERY UNDER GENERAL ANESTHETIC [J].
CARLI, F ;
CLARK, MM ;
WOOLLEN, JW .
BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (10) :1023-1029
[6]   Thermoregulatory vasoconstriction does not impede core warming during cutaneous heating [J].
Clough, D ;
Kurz, A ;
Sessler, DI ;
Christensen, R ;
Xiong, JY .
ANESTHESIOLOGY, 1996, 85 (02) :281-288
[7]   Initial experience with a novel heat-exchanging catheter in neurosurgical patients [J].
Doufas, AG ;
Akça, O ;
Barry, A ;
Petrusca, DA ;
Suleman, MI ;
Morioka, N ;
Guarnaschelli, JJ ;
Sessler, DI .
ANESTHESIA AND ANALGESIA, 2002, 95 (06) :1752-1756
[8]   INVIVO THERMAL-CONDUCTIVITY OF THE HUMAN FOREARM TISSUES [J].
DUCHARME, MB ;
TIKUISIS, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (06) :2682-2690
[9]   FOREARM TEMPERATURE PROFILE DURING THE TRANSIENT PHASE OF THERMAL-STRESS [J].
DUCHARME, MB ;
TIKUISIS, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 64 (05) :395-401
[10]   Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events - A randomized clinical trial [J].
Frank, SM ;
Fleisher, LA ;
Breslow, MJ ;
Higgins, MS ;
Olson, KF ;
Kelly, S ;
Beattie, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (14) :1127-1134