Glutathione measurement in human plasma Evaluation of sample collection, storage and derivatization conditions for analysis of dansyl derivatives by HPLC

被引:423
作者
Jones, DP [1 ]
Carlson, JL
Samiec, PS
Sternberg, P
Mody, VC
Reed, RL
Brown, LAS
机构
[1] Emory Univ, Sch Med, Dept Biochem, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Ophthalmol, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Pediat, Atlanta, GA 30322 USA
关键词
glutathione; plasma; HPLC; fluorescence detection; antioxidants;
D O I
10.1016/S0009-8981(98)00089-8
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Literature values for human plasma GSH vary over 10-fold despite the use of apparently valid analytical procedures for GSH measurement. The purpose of this study was to develop a procedure to minimize error in sample collection, processing and storage that could contribute to such differences. HPLC with fluorescence detection of dansyl derivatives was used for quantification. The results show that collection of blood with a butterfly needle and syringe reduces overestimation due to limited hemolysis and that use of a preservation solution designed to inhibit autooxidation and enzymatic degradation allows quantitative recovery of both GSH and GSSG. Stability tests showed that non-derivatized samples were stable for at least 2 months at - 80 degrees while dansyl derivatives were stable in the dark at 0-4 degrees for 12 months. Results from 59 healthy individuals (20-43 years) provided a mean (+/-1 SD) GSH value of 2.09 +/- 1.14 micromolar. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 16 条