Quantitation of SU11248, an oral multi-target tyrosine kinase inhibitor, and its metabolite in monkey tissues by liquid chromatograph with tandem mass spectrometry following semi-automated liquid-liquid extraction

被引:50
作者
Barattè, S [1 ]
Sarati, S [1 ]
Frigerio, E [1 ]
James, CA [1 ]
Ye, C [1 ]
Zhang, Q [1 ]
机构
[1] Sugen Inc, San Francisco, CA 94080 USA
关键词
SU11248; enzyme inhibitors;
D O I
10.1016/j.chroma.2003.10.085
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
11248 is a potent inhibitor of PDGFR, VEGFR, KIT, and Flt3, and is currently under Phase I clinical evaluation as an anticancer drug. A sensitive and specific analytical method for the quantitation of SU 11248 and its metabolite in several monkey tissues (liver, kidney, brain and white fat) using LC-MS-MS following semi-automated liquid-liquid extraction (LLE) was developed and validated. Amounts of 50 mg of tissue were homogenized using an ultrasonic processor. After addition of the stable labelled internal standard (IS) and ammonium hydroxide (0.3%), samples were extracted with 2.5 ml of tert-butyl methyl ether. Following centrifugation, aliquots of 1.8 ml of the organic phase were transferred into a 96-well plate. The Packard Multiprobe II robotic liquid handler was used to perform all steps mentioned above. The organic phase was dried and the residue was reconstituted with 800 mul of 15 mM ammonium formate buffer solution (pH 3.25) using a Tomtec Quadra. 96 workstation. Aliquots of 10 mul of the resulting solution were injected into the LC-MS-MS system. A Symmetry Shield C-8 column (50 mm x 2.1 mm, 3.5 mum) was used to perform the chromatographic analysis. The mobile phase was 15 mM ammonium formate buffer solution (pH 3.25)-acetonitrile (74:26 (v/v)) with a flow-rate of 0.35 ml/min. Retention times of the metabolite and SU11248 were about 2.5 and 3.5 min, respectively. Total cycle time was 5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurboIonSpray interface and multiple reaction monitoring (MRM) operated in positive ion mode. The method was validated for both compounds over the calibration range of about 2 and 2000 ng/g. The suitability and robustness of the method for in vivo samples were confirmed by analysis of monkey tissues from animals dosed with SU11248. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 12 条
  • [1] [Anonymous], 2001, GUID IND BIOAN METH
  • [2] High-throughput mass spectrometric analysis of xenobiotics in biological fluids
    Bakhtiar, R
    Ramos, L
    Tse, FLS
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (04) : 507 - 540
  • [3] Automated protein precipitation by filtration in the 96-well format
    Biddlecombe, RA
    Pleasance, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 734 (02): : 257 - 265
  • [4] FRIGERIO E, 2002, 24 INT S CHROM 15 20
  • [5] Jemal M, 2000, BIOMED CHROMATOGR, V14, P422, DOI 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO
  • [6] 2-I
  • [7] Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry
    Jemal, M
    Teitz, D
    Ouyang, Z
    Khan, S
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 501 - 508
  • [8] Jemal M, 1999, RAPID COMMUN MASS SP, V13, P97, DOI 10.1002/(SICI)1097-0231(19990130)13:2<97::AID-RCM461>3.0.CO
  • [9] 2-T
  • [10] LOUIE SG, 2002, P 93 ANN M AACR S SA