Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis

被引:86
作者
Moraal, Bastiaan [1 ]
Roosendaal, Stefan D. [1 ]
Pouwels, Petra J. W. [2 ]
Vrenken, Hugo [2 ]
Van Schijndel, Ronald A. [3 ]
Meier, Dominik S.
Guttmann, Charles R. G.
Geurts, Jeroen J. G. [1 ]
Barkhof, Frederik [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, MS Ctr Amsterdam, Dept Radiol, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, MS Ctr Amsterdam, Dept Phys & Med Technol, NL-1081 HV Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, MS Ctr Amsterdam, Dept Informat, NL-1081 HV Amsterdam, Netherlands
基金
美国国家卫生研究院;
关键词
DIR; FLAIR; cortical; infratentorial; flow artifacts;
D O I
10.1007/s00330-008-1009-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To describe signal and contrast properties of an isotropic, single-slab 3D dataset [double inversion-recovery (DIR), fluid-attenuated inversion recovery (FLAIR), T2, and T1-weighted magnetization prepared rapid acquisition gradient-echo (MPRAGE)] and to evaluate its performance in detecting multiple sclerosis (MS) brain lesions compared to 2D T2-weighted spin-echo (T2SE). All single-slab 3D sequences and 2D-T2SE were acquired in 16 MS patients and 9 age-matched healthy controls. Lesions were scored independently by two raters and characterized anatomically. Two-tailed Bonferroni-corrected Student's t-tests were used to detect differences in lesion detection between the various sequences per anatomical area after log-transformation. In general, signal and contrast properties of the 3D sequences enabled improved detection of MS brain lesions compared to 2D-T2SE. Specifically, 3D-DIR showed the highest detection of intracortical and mixed WM-GM lesions, whereas 3D-FLAIR showed the highest total number of WM lesions. Both 3D-DIR and 3D-FLAIR showed the highest number of infratentorial lesions. 3D-T2 and 3D-MPRAGE did not improve lesion detection compared to 2D-T2SE. Multi-contrast, isotropic, single-slab 3D MRI allowed an improved detection of both GM and WM lesions compared to 2D-T2SE. A selection of single-slab 3D contrasts, for example, 3D-FLAIR and 3D-DIR, could replace 2D sequences in the radiological practice.
引用
收藏
页码:2311 / 2320
页数:10
相关论文
共 35 条
[1]  
Bagnato F, 2006, AM J NEURORADIOL, V27, P2161
[2]   MRI in multiple sclerosis: correlation with expanded disability status scale (EDSS) [J].
Barkhof, F .
MULTIPLE SCLEROSIS JOURNAL, 1999, 5 (04) :283-286
[3]   Implementation and evaluation of a new pulse sequence for rapid acquisition of double inversion recovery images for simultaneous suppression of white matter and CSF [J].
Bedell, BJ ;
Narayana, PA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :544-547
[4]   Intracortical multiple sclerosis lesions are not associated with increased lymphocyte infiltration [J].
Bo, L ;
Vedeler, CA ;
Nyland, H ;
Trapp, BD ;
Mork, SJ .
MULTIPLE SCLEROSIS, 2003, 9 (04) :323-331
[5]   Estimating the generalized concordance correlation coefficient through variance components [J].
Carrasco, JL ;
Jover, L .
BIOMETRICS, 2003, 59 (04) :849-858
[6]   Detection of cortical lesions is dependent on choice of slice thickness in patients with multiple sclerosis [J].
Dolezal, Ondrej ;
Dwyer, Michael G. ;
Horakova, Dana ;
Havrdova, Eva ;
Minagar, Alireza ;
Balachandran, Srivats ;
Bergsland, Niels ;
Seidl, Zdenek ;
Vaneckova, Manuela ;
Fritz, David ;
Krasensky, Jan ;
Zivadinov, Robert .
NEUROBIOLOGY OF MULTIPLE SCLEROSIS, 2007, 79 :475-489
[7]   EFNS guidelines on the use of neuroimaging in the management of multiple sclerosis [J].
Filippi, M ;
Rocca, MA ;
Arnold, DL ;
Bakshi, R ;
Barkhof, F ;
De Stefano, N ;
Fazekas, F ;
Frohman, E ;
Wolinsky, JS .
EUROPEAN JOURNAL OF NEUROLOGY, 2006, 13 (04) :313-325
[8]   Guidelines for using quantitative measures of brain magnetic resonance imaging abnormalities in monitoring the treatment of multiple sclerosis [J].
Filippi, M ;
Horsfield, MA ;
Adèr, HJ ;
Barkhof, F ;
Bruzzi, P ;
Evans, A ;
Frank, JA ;
Grossman, RI ;
McFarland, HF ;
Molyneux, P ;
Paty, DW ;
Simon, J ;
Tofts, PS ;
Wolinsky, JS ;
Miller, DH .
ANNALS OF NEUROLOGY, 1998, 43 (04) :499-506
[9]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[10]  
Georgiades CS, 2001, AM J NEURORADIOL, V22, P1732