Note.: Visual and instrumental color evaluation in red wines

被引:265
作者
Martínez, JA
Melgosa, M
Pérez, MM
Hita, E
Negueruela, AI
机构
[1] Univ Granada, Fac Ciencias, Dept Opt, E-18071 Granada, Spain
[2] Univ Zaragoza, Fac Vet, Dept Fis Aplicada, E-50013 Zaragoza, Spain
关键词
wines; color; sensory evaluation; instrumental measurements;
D O I
10.1106/VFAT-5REN-1WK2-5JGQ
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The color of 15 red wines from several wineries within the renowned wine-producing region Rioja (Northern Spain) was measured by spectrophotometric and spectroradiometric techniques and was visually assessed in a pair-comparison experiment by a panel of 10 experienced observers having normal color vision. Correlation between instrumental color measurements made by spectrophotometric and spectroradiometric techniques was very low, as expected from major differences in the experimental conditions employed (different illumination, path lengths and glass effects). Spectroradiometric measurements at the center of the wine sampler and at positions displaced 1 cm in the horizontal and vertical directions were quite different, mainly because of an increase of the lightness L*, the average color differences between them being high (3.5 and 2.6 CIELAB units, respectively). A 50% acceptance percentage resulted for a color difference of 2.8 CIELAB units, using a reference anchor-pair of wine samples with 4.0 CIELAB units. Thus, a value around 3.0 CIELAB units should be considered a preliminary estimate of the acceptable tolerance by the human eye for red wines poured in standard wine samplers.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 31 条
[11]  
DUJARDIN J, 1928, NOTICE INSTRUMENTS P
[12]  
ESCOLAR D, 1993, 943 OIV
[13]  
FRANCIS FJ, 1975, FOOD COLORIMETRY THE
[14]  
GLORIES Y, 1984, Connaissance de la Vigne et du Vin, V18, P253
[15]   INDUSTRIAL COLOR DIFFERENCE - PROGRESS AND PROBLEMS [J].
KUEHNI, RG .
COLOR RESEARCH AND APPLICATION, 1990, 15 (05) :261-265
[16]   COLOR-TOLERANCE DATA AND TENTATIVE CIE 1976 L-STAR A-STAR B-STAR FORMULA [J].
KUEHNI, RG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (05) :497-500
[17]  
LOMAS AM, 1994, OPTICA PURA APLICADA, V27, P70
[18]  
Melgosa M, 1997, COLOR RES APPL, V22, P148, DOI 10.1002/(SICI)1520-6378(199706)22:3<148::AID-COL3>3.0.CO
[19]  
2-R
[20]   Reproducibility of the bromthymol blue standards used for color specification of virgin olive oil [J].
Melgosa, M ;
Pérez, MM ;
Hita, E ;
Heredia, FJ ;
Alba, J ;
Moyano, MJ .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2001, 78 (03) :265-270