Distal femoral allograft reconstruction for massive osteolytic bone loss in revision total knee arthroplasty

被引:15
作者
Bezwada, HP
Shah, AR
Zambito, K
Cerynik, DL
Johanson, NA
机构
[1] Penn Hosp, Penn Orthopaed, Philadelphia, PA 19107 USA
[2] Drexel Univ, Coll Med, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
关键词
allograft; osteolysis; revision total knee arthroplasty; polyethylene wear;
D O I
10.1016/j.arth.2005.06.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Massive osteolytic bone loss in revision total knee arthroplasty has been an uncommon challenge. From 2001 to 2002, 11 knees in 10 patients underwent revision of failed modular PFC (Johnson and Johnson Orthopaedics, Raynham, Mass) total knee arthroplasties with distal femoral allografts and long-stemmed revision implants for massive osteolytic induced femoral bone loss. The mean follow-up was 42 months (range, 36-48 months). Radiographic graft incorporation was demonstrated in all 11 knees with no cases of loosening. The Knee Society Pain Scores improved by an average of 25.4 points, and the function scores improved by an average of 23.3 points. The outcomes of distal femoral allografts in the reconstruction of massive osteolytic bone loss associated with failed modular PFC (Johnson and Johnson Orthopaedics) total knee arthroplasties are favorable.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 29 条
[1]
Cadambi A, 1994, J Arthroplasty, V9, P579, DOI 10.1016/0883-5403(94)90111-2
[2]
Chandler HP, 1996, ORTHOPEDICS, V19, P797
[3]
The use of structural allograft for uncontained defects in revision total knee arthroplasty - A minimum five-year review [J].
Clatworthy, MG ;
Ballance, J ;
Brick, GW ;
Chandler, HP ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (03) :404-411
[4]
Collier MB, 2004, J ARTHROPLASTY, V19, P257
[5]
The structural allograft composite in revision total knee arthroplasty [J].
Dennis, DA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :90-93
[6]
Treatment of major defects of bone with bulk allografts and stemmed components during total knee arthroplasty [J].
Engh, GA ;
Herzwurm, PJ ;
Parks, NL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1030-1039
[7]
POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[8]
Engh GA, 2005, REVISION TOTAL KNEE ARTHROPLASTY, P63, DOI 10.1007/0-387-27085-X_6
[9]
In vivo deterioration of tibial baseplate locking mechanisms in contemporary modular total knee components [J].
Engh, GA ;
Lounici, S ;
Rao, AR ;
Collier, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) :1660-1665
[10]
ENGH GA, 1995, ORTHOP T, V18, P1138