Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging

被引:119
作者
Moerland, MA [1 ]
Wijrdeman, HK [1 ]
Beersma, R [1 ]
Bakker, CJG [1 ]
Battermann, JJ [1 ]
机构
[1] UNIV UTRECHT HOSP, DEPT RADIOL, UTRECHT, NETHERLANDS
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 37卷 / 04期
关键词
implant evaluation; permanent implant; prostatic cancer; magnetic resonance imaging;
D O I
10.1016/S0360-3016(96)00575-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study is the evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging (MRI). Methods and Materials: Twenty-one patients underwent radiography on the simulator and MRI within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the seed-induced signal voids on MRI provided the seed positions in relation to the prostate. The prostate was contoured on the transversal magnetic resonance images, and dose-volume histograms were computed to evaluate the implants. The validity of the ellipsoidal prostate volume approximation, as applied in preimplant dose calculation, was assessed by comparison of ellipsoidal volumes given by prostate width, height, and length and prostate volumes obtained by a slice-by-slice contouring method, both on postimplant MRI. Prostate volume changes due to postimplant prostate swelling were assessed from radiographs taken at 3 days and 1 month after the implantation. Results: The seeds were readily identified on T-1-weighted spin-echo images and matched with the seed distribution reconstructed from the isocentric radiographs. The matching error, averaged over 21 patients, amounted to 1.8 +/- 0.4 mm (mean +/- standard deviation). The fractions of the prostate volumes receiving the prescribed matched peripheral dose (MPD) ranged from 32 to 71% (mean +/- standard deviation: 60 +/- 10%). Prostate volumes, obtained by the contouring method on postimplant MRI, were a factor 1.5 +/- 0.3 larger than the ellipsoidal volumes given by the prostate dimensions on postimplant MRI. Prostate volumes 3 days after the implantation were a factor 1.3 +/- 0.2 larger than the prostate volumes 1 month after the implantation. Registration of the reconstructed seed distribution and the MR images showed inaccuracies in seed placement, for example, two or more seeds clustering together or seeds outside the prostate. Conclusions: Registration of the reconstructed seed distribution and the MR images enabled evaluation of target coverage, which amounted to 60 +/- 10%. The discrepancy between prescribed dose and realized dose was caused by underestimation of the preimplant prostate volume due to the ellipsoidal approximation, postimplant prostate swelling at the time of evaluation, and inaccuracies in seed placement. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:927 / 933
页数:7
相关论文
共 20 条
  • [11] TRANSPERINEAL I125 SEED IMPLANTATION IN PROSTATIC-CANCER GUIDED BY TRANS-RECTAL ULTRASONOGRAPHY
    HOLM, HH
    JUUL, N
    PEDERSEN, JF
    HANSEN, H
    STROYER, I
    [J]. JOURNAL OF UROLOGY, 1983, 130 (02) : 283 - 286
  • [12] PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT
    LING, CC
    YORKE, ED
    SPIRO, IJ
    KUBIATOWICZ, D
    BENNETT, D
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11): : 1747 - 1752
  • [13] ANALYSIS AND CORRECTION OF GEOMETRIC DISTORTIONS IN 1.5-T MAGNETIC-RESONANCE IMAGES FOR USE IN RADIOTHERAPY TREATMENT PLANNING
    MOERLAND, MA
    BEERSMA, R
    BHAGWANDIEN, R
    WIJRDEMAN, HK
    BAKKER, CJG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (10) : 1651 - 1664
  • [14] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234
  • [15] ACCURACY OF INVIVO ASSESSMENT OF PROSTATIC VOLUME BY MRI AND TRANSRECTAL ULTRASONOGRAPHY
    RAHMOUNI, A
    YANG, A
    TEMPANY, CMC
    FRENKEL, T
    EPSTEIN, J
    WALSH, P
    LEICHNER, PK
    RICCI, C
    ZERHOUNI, E
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) : 935 - 940
  • [16] A CT-BASED EVALUATION METHOD FOR PERMANENT IMPLANTS - APPLICATION TO PROSTATE
    ROY, JN
    WALLNER, KE
    HARRINGTON, PJ
    LING, CC
    ANDERSON, LL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (01): : 163 - 169
  • [17] STARK DD, 1992, MAGNETIC RESONANCE I
  • [18] ULTRASONICALLY GUIDED TRANSPERINEAL SEED IMPLANTATION OF THE PROSTATE - MODIFICATION OF THE TECHNIQUE AND QUALITATIVE ASSESSMENT OF IMPLANTS
    VANTRIET, A
    TELOO, HJ
    YPMA, AFGVM
    MAK, ACA
    VANSLOOTEN, FHS
    HOEKSTRA, CJM
    KROESE, MCS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (03): : 555 - 558
  • [19] ANALYSIS OF BIOPSY FINDINGS AND IMPLANT QUALITY FOLLOWING ULTRASONICALLY-GUIDED I-125 IMPLANTATION FOR LOCALIZED PROSTATIC-CARCINOMA
    VIJVERBERG, PLM
    BLANK, LECM
    DABHOIWALA, NF
    DEREIJKE, TM
    KOEDOODER, C
    HART, AAM
    KURTH, KH
    GONZALEZ, DG
    [J]. BRITISH JOURNAL OF UROLOGY, 1993, 72 (04): : 470 - 477
  • [20] RETROPUBIC IMPLANTATION OF IODINE 125 IN TREATMENT OF PROSTATIC CANCER
    WHITMORE, WF
    GRABSTALD, H
    HILARIS, B
    [J]. JOURNAL OF UROLOGY, 1972, 108 (06) : 918 - +