breast neoplasm;
computer-assisted;
power Doppler imaging;
ultrasound (US);
contrast media;
Doppler studies;
D O I:
10.1016/j.ejrad.2004.04.017
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 [临床医学];
100207 [影像医学与核医学];
1009 [特种医学];
摘要:
Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound. (C) 2004 Elsevier Ireland Ltd. All rights reserved.