Validation and utility of novel volume reduction technique for determination of parallel conductance

被引:6
作者
White, PA
Brookes, CIO
Ravn, H
Hjortdal, V
Chaturvedi, RR
Redington, AN
机构
[1] Great Ormond St Hosp Children, Cardiothorac Unit, London WC1N 3JH, England
[2] Royal Brompton Hosp, Dept Cardiol, London SW3 6NP, England
[3] Skejby Univ Hosp, Inst Expt Clin Res, DK-8200 Aarhus, Denmark
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 280卷 / 01期
关键词
saline dilution; right ventricle; left ventricle; ventricular volume; conductance catheter;
D O I
10.1152/ajpheart.2001.280.1.H475
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The parallel conductance volume, created by the conductivity of structures surrounding the ventricular blood pool, can be estimated by using a saline dilution technique. This paper examines the use of a novel volume reduction method, during a standard vena caval preload reduction maneuver, as an alternative to the routinely used saline dilution method to calibrate conductance catheter measurements in the left (LV) and right ventricle (RV) of animals and humans. The serial reproducibility of both methods was examined by measurement of percent difference, and by assessing the coefficient of repeatability 1) between two measurements within the same subject, 2) between the two techniques, and 3) interobserver variability. The effect of ventricular size and contractile state on the volume reduction technique was also observed. It was essential to ensure the technique was not affected by inotropic state. The volume reduction technique and saline dilution method were repeated at three different loading states (baseline, 5, and 10 mug.kg(-1).min(-1) of dobutamine). The coefficient of repeatability between serial measurements was similar for both the volume reduction and saline dilution methods, and good interobserver variability was demonstrated. The volume reduction technique was compared with the saline dilution technique over a large range of ventricular sizes. No significant difference was observed in the RV or LV of adult humans or in the LV of neonatal pigs and children. There was no significant effect on either the saline dilution or the volume reduction technique as the inotropic state increased. In conclusion, the volume reduction technique is neither affected by ventricular size nor contractile state, is repeatable between different observers, and can be used to substitute the saline dilution method when preload reduction of the ventricle is being employed.
引用
收藏
页码:H475 / H482
页数:8
相关论文
共 29 条
  • [1] SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (02) : 638 - 648
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] Baan J., 1989, Automedica, V11, P357
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [6] Validation of a new intraoperative technique to evaluate load-independent indices of right ventricular performance in patients undergoing cardiac operations
    Brookes, CIO
    White, PA
    Bishop, AJ
    Oldershaw, PJ
    Redington, AN
    Noat, NE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (03) : 468 - 476
  • [7] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [8] CONTRACTILITY-DEPENDENT CURVILINEARITY OF END-SYSTOLIC PRESSURE-VOLUME RELATIONS
    BURKHOFF, D
    SUGIURA, S
    YUE, DT
    SAGAWA, K
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : H1218 - H1227
  • [9] Left ventricular dysfunction after open repair of simple congenital heart defects in infants and children: Quantitation with the use of a conductance catheter immediately after bypass
    Chaturvedi, RR
    Lincoln, C
    Gothard, JWW
    Scallan, MH
    White, PA
    Redington, AN
    Shore, DF
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (01) : 77 - 83
  • [10] DICKSTEIN ML, 1995, CARDIOVASC RES, V29, P820, DOI 10.1016/0008-6363(96)88618-4