Highly ordered platinum-nanotubule arrays for amperometric glucose sensing

被引:417
作者
Yuan, JH [1 ]
Wang, K [1 ]
Xia, XH [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
关键词
D O I
10.1002/adfm.200400321
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Direct glucose sensing on highly ordered platinum-nanotubule array electrodes (NTAEs) is systematically investigated. The NTAEs are fabricated by electrochemical deposition of platinum in a 3-aminopropyltrimetlioxysilane-modified anodic alumina membrane. Their structures and morphologies are then characterized using X-ray diffraction and scanning electron microscopy, respectively. Electrochemical results show that NTAEs with different real surface areas could be achieved by controlling the deposition time or by using anodic alumina membranes with different pore size. Electrochemical responses of the as-synthesized NTAEs to glucose in a solutions of either 0.5 M H2SO4, or phosphate-buffered saline (PBS, pH 7.4) containing 0.1 M KCl are discussed. Based on the different electrochemical reaction mechanisms of glucose and interferents such asp-acetamedophenol and ascorbic acid, their high roughness factor makes NTAEs sensitive, selective, and stable enough to be a kind of biosensor for the non-enzymatic detection of glucose. Such a glucose sensor allows the determination of glucose in the linear range 2-14 mM, with a sensitivity of 0.1 mu A cm(-2) mM(-1) (correlation coefficient 0.999), and a detection limit of 1.0 mu M glucose, with neglectable interference from physiological levels of 0.1 mM p-acetamedophenol, 0.1 mM ascorbic acid, and 0.02 mM uric acid.
引用
收藏
页码:803 / 809
页数:7
相关论文
共 27 条
[1]   A modular electrochemical sensor for saccharides [J].
Arimori, S ;
Ushiroda, S ;
Peter, LM ;
Jenkins, ATA ;
James, TD .
CHEMICAL COMMUNICATIONS, 2002, (20) :2368-2369
[2]  
Bao JC, 2001, ADV MATER, V13, P1631, DOI 10.1002/1521-4095(200111)13:21<1631::AID-ADMA1631>3.0.CO
[3]  
2-R
[4]   TEMPLATE SYNTHESIS OF METAL MICROTUBULES [J].
BRUMLIK, CJ ;
MARTIN, CR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (08) :3174-3175
[5]   A rapid and easy procedure of biosensor fabrication by microencapsulation of enzyme in hydrophilic synthetic latex films. Application to the amperometric determination of glucose [J].
Cosnier, S ;
Szunerits, S ;
Marks, RS ;
Novoa, A ;
Puech, L ;
Perez, E ;
Rico-Lattes, I .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (12) :851-855
[6]   ANODIC OXIDE FILMS ON ALUMINUM [J].
DIGGLE, JW ;
DOWNIE, TC ;
GOULDING, CW .
CHEMICAL REVIEWS, 1969, 69 (03) :365-&
[7]   Picoamperometric detection of glucose at ultrasmall platinum-based biosensors: Preparation and characterization [J].
Hrapovic, S ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3308-3315
[8]   CHARACTERIZATION AND STABILIZATION OF ENZYME BIOSENSORS [J].
KATAKIS, I ;
DOMINGUEZ, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :310-319
[9]   STRUCTURAL FEATURES OF OXIDE COATINGS ON ALUMINIUM [J].
KELLER, F ;
HUNTER, MS ;
ROBINSON, DL .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1953, 100 (09) :411-419
[10]   AMPEROMETRIC BIOSENSOR BASED ON DIRECT COMMUNICATION BETWEEN GLUCOSE-OXIDASE AND A CONDUCTING POLYMER INSIDE THE PORES OF A FILTRATION MEMBRANE [J].
KOOPAL, CGJ ;
DERUITER, B ;
NOLTE, RJM .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1991, (23) :1691-1692