Validation of the ambient TUG chair with light barriers and force sensors in a clinical trial

被引:12
作者
Fudickar, Sebastian [1 ]
Kiselev, Joern [2 ]
Frenken, Thomas [3 ]
Wegel, Sandra [2 ]
Dimitrowska, Slavica [2 ]
Steinhagen-Thiessen, Elisabeth [2 ]
Hein, Andreas [1 ,3 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Sch Med & Hlth Sci, Dept Hlth Serv Res, Oldenburg, Germany
[2] Charite Univ Med Berlin, Geriatr Res Grp, Berlin, Germany
[3] OFFIS Inst Informat Technol, Oldenburg, Germany
关键词
assessment; falls; older adults; mobility; COMPREHENSIVE GERIATRIC ASSESSMENT; QUALITY-OF-LIFE; OLDER-ADULTS; GO TEST; PHYSICAL-ACTIVITY; MUSCLE STRENGTH; MOBILITY; FRAILTY; PEOPLE; VALIDITY;
D O I
10.1080/10400435.2018.1446195
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
To initiate appropriate interventions and avoid physical decline, comprehensive measurements are needed to detect functional changes in elderly people at the earliest possible stage. The established Timed Up&Go (TUG) test takes little time and, due to its standardized and easy procedure, can be conducted by elderly people in their own homes without clinical guidance. Therefore, cheap light barriers (LBs) and force sensors (FSs) are well suited ambient sensors that could easily be attached to existing (arm)chairs to measure and report TUG times in order to identify functional decline. We validated the sensitivity of these sensors in a clinical trial with 100 elderlies aged 58-92 years with a mean of 74 (+/- 6.78) years by comparing the sensor-based results with standard TUG measurements using a stopwatch. We further evaluated the accuracy enhancement when calibrating the algorithm via a mixed linear model. With calibration, the LBs achieved a root mean square error (RMSE) of 0.83 s, compared to 1.90 s without, and the FSs achieved 0.90 s compared to 2.12 s without. The suitability of measuring accurate TUG times with each of the ambient sensors and of measuring TUG regularly in the homes of elderly people could be confirmed.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 46 条
[1]
Angevaren M, 2008, COCHRANE DB SYST REV, DOI [10.1002/14651858.CD005381.pub2, 10.1002/14651858.CD005381.pub3]
[2]
[Anonymous], MED MEASUREMENTS APP
[3]
[Anonymous], P 6 INT PERV COMP TE
[4]
BERG KO, 1992, ARCH PHYS MED REHAB, V73, P1073
[5]
Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait [J].
Bilney, B ;
Morris, M ;
Webster, K .
GAIT & POSTURE, 2003, 17 (01) :68-74
[6]
Reliability and concurrent validity of the Expanded Timed Up-and-Go test in older people with impaired mobility [J].
Botolfsen, Pernille ;
Helbostad, Jorunn L. ;
Moe-Nilssen, Rolf ;
Wall, James C. .
PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2008, 13 (02) :94-106
[7]
Exercise and Physical Activity for Older Adults [J].
Chodzko-Zajko, Wojtek J. ;
Proctor, David N. ;
Singh, Maria A. Fiatarone ;
Minson, Christopher T. ;
Nigg, Claudio R. ;
Salem, George J. ;
Skinner, James S. .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2009, 41 (07) :1510-1530
[8]
Meta-analysis of Quality-of-Life Outcomes From Physical Activity Interventions [J].
Conn, Vicki S. ;
Hafdahl, Adam R. ;
Brown, Lori M. .
NURSING RESEARCH, 2009, 58 (03) :175-183
[9]
Effects of physical exercise interventions in frail older adults: a systematic review of randomized controlled trials [J].
de Labra, Carmen ;
Guimaraes-Pinheiro, Christyanne ;
Maseda, Ana ;
Lorenzo, Trinidad ;
Millan-Calenti, Jose C. .
BMC GERIATRICS, 2015, 15
[10]
Dibble Lee E, 2006, J Neurol Phys Ther, V30, P60