Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test?

被引:26
作者
Lima-Oliveira, Gabriel [1 ,2 ,3 ,4 ]
Lippi, Giuseppe [5 ]
Salvagno, Gian Luca [1 ]
Montagnana, Martina [1 ]
Picheth, Geraldo [2 ]
Guidi, Gian Cesare [1 ,2 ]
机构
[1] Univ Verona, Dept Life & Reprod Sci, Lab Clin Biochem, I-37100 Verona, Italy
[2] Univ Fed Parana, Dept Med Pathol, Postgrad Program Pharmaceut Sci, BR-80060000 Curitiba, Parana, Brazil
[3] MERCOSUL Sect Comm Clin Anal & Vitro Diagnost CSM, Rio De Janeiro, Brazil
[4] Brazilian Soc Clin Anal Sao Paulo State, Sao Paulo, Brazil
[5] Azienda Osped Univ Parma, UO Diagnost Ematochim, Parma, Italy
关键词
Blood specimen collection; Blood gas; Heparin; Intensive care unit; ISO; 15189; Preanalytical variability; Syringe; IONIZED CALCIUM; BIOLOGICAL VARIATION; QUALITY IMPROVEMENT; OXYGEN-TENSION; ARTERIAL-BLOOD; HEPARIN;
D O I
10.1016/j.clinbiochem.2012.03.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: Evaluate whether four different brands/types of heparin coated syringes can represent a source of variability in blood gas analysis (BGA). Design and methods: Blood was collected from one hundred volunteers into different syringes: Syringe I (lithium heparin and calcium balanced); Syringe II: in-house prepared (sodium heparin); Syringe III: (spray-dried calcium-balanced lithium heparin); Syringe IV (lyophilized electrolyte-balanced lithium heparin). Results: Significant differences were as follows: a) Syringe I vs II: pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), base excess (BE), total hemoglobin (tHb), sodium (Na+), potassium (K+), calcium (Ca2+), glucose (Glu), lactate (Lac), O-2 Hb and p 50; b) Syringe I vs III: pH, pO(2), cHCO(3)(-), ctCO(2), BE, Na+, Glu, Lac and p 50; c) Syringe I vs IV: pH, pO(2), sO(2), pCO(2)(t), BE, Na+, K+, Ca2+, Glu, Lac and O-2 Hb; d) Syringe II vs III: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), ctO(2), tHb, Na+, K+, Ca2+, Lac, and p 50; e) Syringe II vs IV: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), BE, tHb, Na+, K+, Ca2+, Lac, O-2 Hb and p 50; f) Syringe III vs IV: pH, pO(2), sO(2), cHCO(3)(-), ctCO(2), ctO(2), BE, Na+, K+, Ca2+, O-2 Hb and p 50. Conclusion: The different manufacturers of syringes can represent new source of variability on BGA. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 41 条
[21]   Risk management in the preanalytical phase of laboratory testing [J].
Lippi, Giuseppe ;
Guidi, Gian Cesare .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (06) :720-727
[22]  
Lippi G, 2006, CLIN LAB, V52, P457
[23]   Prevalence of hemolytic specimens referred for arterial blood gas analysis [J].
Lippi, Giuseppe ;
Ippolito, Luigi ;
Fontana, Rossana .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (05) :931-932
[24]  
Lu JY, 2003, J FORMOS MED ASSOC, V102, P246
[25]   Is the Calcium Correct? Measuring Serum Calcium in Dialysis Patients [J].
Morton, A. Ross ;
Garland, Jocelyn S. ;
Holden, Rachel M. .
SEMINARS IN DIALYSIS, 2010, 23 (03) :283-289
[26]  
NCCLS, 2001, C31A2 NCCLS
[27]  
NCCLS, 2004, H11A4 NCCLS
[28]   Improving reliability of clinical care practices for ventilated patients in the context of a patient safety improvement initiative [J].
Pinto, Anna ;
Burnett, Susan ;
Benn, Jonathan ;
Brett, Stephen ;
Parand, Anam ;
Iskander, Sandra ;
Vincent, Charles .
JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2011, 17 (01) :180-187
[29]  
Plebani M, 1997, CLIN CHEM, V43, P1348
[30]  
Plebani M, 2012, CLIN CHEM LAB MED, V50, P189, DOI [10.1515/CCLM.2011.751, 10.1515/cclm.2011.751]