Evaluation of time-of-flight mass spectrometric detection for fast gas chromatography

被引:97
作者
van Deursen, MM
Beens, J
Janssen, HG
Leclercq, PA
Cramers, CA
机构
[1] Eindhoven Univ Technol, Dept Chem, Instrumental Anal Lab, NL-5600 MB Eindhoven, Netherlands
[2] Unilever Res Labs Vlaardingen, Cent Analyt Sci Unit, NL-3130 AC Vlaardingen, Netherlands
关键词
gas chromatography; fast; mass spectrometry; alkanes; benzene; toluene;
D O I
10.1016/S0021-9673(00)00300-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separations below 1 s of a mixture of organic compounds ranging from C-5 to C-8 have been performed to investigate the performance of a time-of-flight mass spectrometer in fast gas chromatography. The gaseous samples were focussed on a cold trap, and then injected after thermal desorption to obtain the required narrow input band-widths. Also, to obtain a very fast separation, a short narrow bore column was used, operated at above-optimum inlet pressures. With this system, it was possible to identify ten compounds within 500 ms, showing peak-widths (2.354 sigma) as narrow as 12 ms. The spectral acquisition rate used for these analyses was 500 Hz. The quality of the recorded spectra and the comparison with library spectra was very high. Deconvolution algorithms offer the possibility of identifying overlapping peaks. It is shown that the spectral scan speed of the time-of-flight mass spectrometer is high enough for very fast separations. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 19 条
[1]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[2]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[3]  
Dagan S, 1996, J AM SOC MASS SPECTR, V7, P737, DOI 10.1016/1044-0305(96)80519-8
[4]  
Davis SC, 1999, RAPID COMMUN MASS SP, V13, P237, DOI 10.1002/(SICI)1097-0231(19990228)13:4<237::AID-RCM446>3.0.CO
[5]  
2-0
[6]  
DEZEEUW J, 1999, P 21 INT S CAP CHROM, P16
[7]   Peak distortion, data sampling errors and the integrator in the measurement of very narrow chromatographic peaks [J].
Dyson, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :321-340
[8]   IMPROVEMENT OF SPEED OF SEPARATION IN PACKED-COLUMN GAS-CHROMATOGRAPHY [J].
JONKER, RJ ;
POPPE, H ;
HUBER, JFK .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2447-2456
[9]  
LECLERCQ PA, 1985, J HIGH RES CHROMATOG, V8, P764, DOI 10.1002/jhrc.1240081112
[10]   Tunable-column selectivity and time-of-flight detection for high-speed GC/MS [J].
Leonard, C ;
Sacks, R .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5177-5184