Statistical comparison of DLT versus ILSSC in the calibration of a photogrammetric stereo-system

被引:6
作者
Borghese, NA [1 ]
Cerveri, P [1 ]
Ferrigno, GC [1 ]
机构
[1] POLITECN MILAN, CTR BIOINGN, FDN DONGNOCCHI, I-20148 MILAN, ITALY
关键词
calibration; accuracy; reliability; computational time;
D O I
10.1016/S0021-9290(96)00145-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper compares the DLT and ILSSC approaches in the geometrical calibration of a photogrammetric stereo-system in terms of accuracy and speed. To come up with an unbiased quantitative evaluation of the accuracy of the algorithms, the concept of reliable estimate has been introduced: the statistical distribution of the accuracy is assessed over different calibration experiments performed with the same data but with different noise distribution and different test sets. Results show that in the simulations where the only error on the two-dimensional points was Gaussian, zero mean, and on real data which were corrected for distortions through polynomial or linear interpolation, the accuracy of the two methods was quite similar. DLT showed more accurate than ILSSC on simulated data with residual distortion errors and on real data which were not corrected for distortions. As far as speed is concerned, a fast triangulation algorithm is associated with ILSSC while the simultaneous solution of two pairs of DLT equations is associated to DLT. The first algorithm is much faster, requiring 113 flops per point versus 259 of DLT; the fast triangulation with DLT parameters does not achieve the same accuracy on the reconstructed three-dimensional position. Taken all together the results suggest that ILSSC can be theoretically considered the best approach to three-dimensional reconstruction, provided that distortions are corrected in advance. The statistical evaluation of the accuracy allows a fair judgement of the performances of the algorithms to be obtained, unbiased by particular distributions of measurement errors and test points. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 21 条
[1]  
Abdel-Aziz Y. I., 1971, P ASP UI S CLOS RANG
[2]   AN ANALYSIS OF CAMERA NOISE [J].
BOIE, RA ;
COX, IJ .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (06) :671-674
[3]   AN ALGORITHM FOR 3-D AUTOMATIC MOVEMENT DETECTION BY MEANS OF STANDARD TV CAMERAS [J].
BORGHESE, NA ;
FERRIGNO, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) :1221-1225
[4]   ACCURACY ASSESSMENT AND CONTROL POINT CONFIGURATION WHEN USING THE DLT FOR PHOTOGRAMMETRY [J].
CHALLIS, JH ;
KERWIN, DG .
JOURNAL OF BIOMECHANICS, 1992, 25 (09) :1053-1058
[5]   3-DIMENSIONAL CINEMATOGRAPHY WITH CONTROL OBJECT OF UNKNOWN SHAPE [J].
DAPENA, J ;
HARMAN, EA ;
MILLER, JA .
JOURNAL OF BIOMECHANICS, 1982, 15 (01) :11-19
[6]  
Ehara Y., 1995, GAIT POSTURE, V3, P166, DOI DOI 10.1016/0966-6362(95)99067-U
[7]   ELITE - A DIGITAL DEDICATED HARDWARE SYSTEM FOR MOVEMENT ANALYSIS VIA REAL-TIME TV SIGNAL-PROCESSING [J].
FERRIGNO, G ;
PEDOTTI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (11) :943-950
[8]   STEREOMETRY IN VERY CLOSE-RANGE STEREOPHOTOGRAMMETRY WITH NONMETRIC CAMERAS FOR HUMAN MOVEMENT ANALYSIS [J].
FIORETTI, S ;
GERMANI, A ;
LEO, T .
JOURNAL OF BIOMECHANICS, 1985, 18 (11) :831-842
[9]   COMPARATIVE-ASSESSMENT OF 2 ALGORITHMS FOR CALIBRATING STEREOPHOTOGRAMMETRIC SYSTEMS [J].
GAZZANI, F .
JOURNAL OF BIOMECHANICS, 1993, 26 (12) :1449-1454
[10]  
GOLUB G, 1977, 491 U WISC MAD DEP S