Incidence of periprocedural myocardial infarction following stent implantation: Comparison between first- and second-generation drug-eluting stents

被引:11
作者
Tandjung, Kenneth [1 ]
Basalus, Mounir W. Z. [1 ]
Muurman, Esther [1 ]
Louwerenburg, Hans W. [1 ]
van Houwelingen, K. Gert [1 ]
Stoel, Martin G. [1 ]
de Man, Frits H. A. F. [1 ]
Jansen, Hanneke [1 ]
Huisman, Jennifer [1 ]
Linssen, Gerard C. M. [2 ]
Droste, Herman T. [3 ]
Nienhuis, Mark B. [4 ]
von Birgelen, Clemens [1 ,5 ]
机构
[1] Thoraxctr Twente, Dept Cardiol, NL-7513 ER Enschede, Netherlands
[2] Hosp Grp Twente, Dept Cardiol, Almelo, Netherlands
[3] Hosp Grp Twente, Dept Cardiol, Hengelo, Netherlands
[4] Queen Beatrix Hosp, Dept Cardiol, Winterswijk, Netherlands
[5] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
periprocedural myocardial infarction; drug-eluting stent; cardiac biomarkers; percutaneous coronary intervention; coronary artery disease; PERCUTANEOUS CORONARY INTERVENTION; CREATINE KINASE-MB; TROPONIN-T; ACUTE CATHETERIZATION; DURABLE POLYMER; ISCHEMIC EVENTS; ARTERY-DISEASE; MORTALITY RISK; Q-WAVE; ELEVATION;
D O I
10.1002/ccd.23334
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: First- and second-generation drug-eluting stents (DES) differ in coating materials, which may influence the incidence of periprocedural myocardial infarction (PMI). Objective: To compare the incidence of PMI between first- and second-generation DES, using the current Academic Research Consortium (ARC) definition of PMI. Methods: We assessed 800 patients treated with first- (Taxus Liberte or Endeavor) or second-generation DES (Xience V or Resolute). Each DES group consisted of 200 consecutive patients, who were treated during the transition from first- to second-generation DES. Routine peri-interventional assessment of cardiac biomarkers was performed to compare the incidence of PMI between DES groups according to the updated definition by the ARC: 2x upper reference limit of creatine kinase (CK), confirmed by CK-MB elevation. Results: In 800 patients, a total of 1,522 DES (363 Taxus; 385 Endeavor; 382 Xience V; 392 Resolute) were implanted to treat 1,232 lesions. Patient characteristics did not differ between groups. In patients receiving second-generation DES, more multivessel percutaneous coronary interventions were performed (P = 0.01). The overall incidence of PMI was 4.75%. Between first- and second-generation DES, there was no significant difference in PMI (5.5% vs. 4.0%; P = 0.29). In a multivariate analysis, only the total number of stents implanted (P < 0.001) and presentation with acute coronary syndrome (P = 0.02) were independent predictors of PMI. Conclusion: Using the revised ARC definition, we found no significant difference in PMI between first- and second-generation DES. Overall, PMI occurred in 4.75%, which is 58% lower than with use of the historical PMI definition. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:524 / 530
页数:7
相关论文
共 45 条
[1]   TWENTE Study: The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente: study design, rationale and objectives [J].
Basalus, M. W. Z. ;
Tandjung, K. ;
van Houwelingen, K. G. ;
Stoel, M. G. ;
de Man, F. H. A. F. ;
Louwerenburg, J. W. ;
Said, S. A. M. ;
Linssen, G. C. M. ;
Kleijne, M. A. W. J. ;
van der Palen, J. ;
Huisman, J. ;
Verhorst, P. M. J. ;
von Birgelen, C. .
NETHERLANDS HEART JOURNAL, 2010, 18 (7-8) :360-364
[2]  
Basalus MWZ, 2010, EUROINTERVENTION, V6, P141, DOI 10.4244/
[3]   Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy [J].
Basalus, Mounir W. Z. ;
Ankone, Marc J. K. ;
van Houwelingen, K. Gert ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (01) :157-165
[4]   Impact of atherosclerotic plaque composition on coronary microembolization during percutaneous coronary interventions [J].
Boese, Dirk ;
von Birgelen, Clemens ;
Zhou, Xiu Ying ;
Schmermund, Axel ;
Philipp, Sebastian ;
Sack, Stefan ;
Konorza, Thomas ;
Moehlenkamp, Stefan ;
Leineweber, Kirsten ;
Kleinbongard, Petra ;
Wijns, William ;
Heusch, Gerd ;
Erbel, Raimund .
BASIC RESEARCH IN CARDIOLOGY, 2008, 103 (06) :587-597
[5]   Myonecrosis after revascularization procedures [J].
Califf, RM ;
Abdelmeguid, AE ;
Kuntz, RE ;
Popma, JJ ;
Davidson, CJ ;
Cohen, EA ;
Kleiman, NS ;
Mahaffey, KW ;
Topol, EJ ;
Pepine, CJ ;
Lipicky, RJ ;
Granger, CB ;
Harrington, RA ;
Tardiff, BE ;
Crenshaw, BS ;
Bauman, RP ;
Zuckerman, BD ;
Chaitman, BR ;
Bittl, JA ;
Ohman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :241-251
[6]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[7]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[8]   Death following creatine kinase-MB elevation after coronary intervention - Identification of an early risk period: Importance of creatine kinase-MB level, completeness of revascularization, ventricular function, and probable benefit of statin therapy [J].
Ellis, SG ;
Chew, D ;
Chan, A ;
Whitlow, PL ;
Schneider, JP ;
Topol, EJ .
CIRCULATION, 2002, 106 (10) :1205-1210
[9]   Coronary Stents Current Status [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S1-S42
[10]   ROUGHNESS AND THROMBOGENICITY OF THE OUTER SURFACES OF INTRAVASCULAR CATHETERS [J].
HECKER, JF ;
SCANDRETT, LA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (04) :381-395