ROUGHNESS AND THROMBOGENICITY OF THE OUTER SURFACES OF INTRAVASCULAR CATHETERS

被引:61
作者
HECKER, JF [1 ]
SCANDRETT, LA [1 ]
机构
[1] UNIV NEW S WALES,CTR BIOMED ENGN,KENSINGTON,NSW 2033,AUSTRALIA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1985年 / 19卷 / 04期
关键词
POLYETHYLENES - Biocompatibility - POLYURETHANES - Biocompatibility - POLYVINYL CHLORIDE - Biocompatibility - SILICONES - Biocompatibility - SURFACES - Roughness Measurement;
D O I
10.1002/jbm.820190404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thirty-seven types of catheters made from plastic including silicone rubber, polyvinylchloride, polyethylene, and polyurethane were tested for thrombogenesis in the cephalic vein of sheep. The range in the mass of thrombus on the catheters at autopsy 9 days after insertion was 20-fold. There was considerable variation when catheters made from the same types of plastic were compared, but polyethylene catheters tended to be more thrombogenic than other types. Scanning electron microscopy (SEM) revealed a variety of surfaces ranging from very smooth to very rough. Roughness was frequently associated with the presence of radio-opaque particles which in several catheters were concentrated into radio-opaque tracer strips. Within types of plastics, catheters with rougher surfaces were usually more thrombogenic than those with smooth surfaces.
引用
收藏
页码:381 / 395
页数:15
相关论文
共 34 条
[1]   THROMBOSIS AFTER CENTRAL VENOUS CANNULATION [J].
AHMED, N ;
PAYNE, RF .
MEDICAL JOURNAL OF AUSTRALIA, 1976, 1 (08) :217-220
[2]   SCANNING ELECTRON-MICROSCOPIC STUDY OF ANGIOGRAPHIC CATHETERS AND GUIDE WIRES [J].
ANDERSON, JH ;
GIANTURCO, C ;
WALLACE, S ;
DODD, GD .
RADIOLOGY, 1974, 111 (03) :567-571
[3]  
BERGER S, 1979, PROGR HEMOSTASIS THR, P273
[4]   SCANNING ELECTRON-MICROSCOPY OF SURFACE IRREGULARITIES AND THROMBOGENESIS OF POLYURETHANE AND POLYETHYLENE CORONARY CATHETERS [J].
BOURASSA, MG ;
CANTIN, M ;
SANDBORN, EB ;
PEDERSON, E .
CIRCULATION, 1976, 53 (06) :992-996
[5]  
CLAWSON CC, 1978, PEDIATRICS, V62, P702
[6]   MULTIPLE RANGE AND MULTIPLE F TESTS [J].
DUNCAN, DB .
BIOMETRICS, 1955, 11 (01) :1-42
[7]   COMPARISON OF THROMBOGENICITY OF COMMERCIALLY AVAILABLE CATHETERS [J].
DURST, S ;
LESLIE, J ;
MOORE, R ;
AMPLATZ, K .
RADIOLOGY, 1974, 113 (03) :599-600
[8]   CLOTTING ACTIVITY OF MATERNAL AND FOETAL SHEEP BLOOD [J].
FANTL, P ;
WARD, HA .
JOURNAL OF PHYSIOLOGY-LONDON, 1960, 150 (03) :607-620
[9]  
GAJEWSKI J, 1971, AM J VET RES, V32, P405
[10]   COMPLICATIONS OF INDWELLING CHEMOTHERAPY CATHETERS [J].
GOLDMAN, ML ;
BILBAO, MK ;
ROSCH, J ;
DOTTER, CT .
CANCER, 1975, 36 (06) :1983-1990