Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy

被引:277
作者
Abramoff, Michael D. [1 ]
Folk, James C. [1 ]
Han, Dennis P. [1 ]
Walker, Jonathan D. [1 ]
Williams, David F. [1 ]
Russell, Stephen R. [1 ]
Massin, Pascale [1 ]
Cochener, Beatrice [1 ]
Gain, Philippe [1 ]
Tang, Li [1 ]
Lamard, Mathieu [1 ]
Moga, Daniela C. [1 ]
Quellec, Gwenole [1 ]
Niemeijer, Meindert [1 ]
机构
[1] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
COLOR FUNDUS PHOTOGRAPHS; MACULAR EDEMA; COST-EFFECTIVENESS; RANIBIZUMAB; SPECIFICITY; SENSITIVITY; POPULATION;
D O I
10.1001/jamaophthalmol.2013.1743
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Importance: The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. Objective: To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). Design and Setting: In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. Participants: A total of 874 people with diabetes at risk for DR. Main Outcome Measures: Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (kappa). Results: The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader kappa was 0.822. Conclusions: The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment. JAMA Ophthalmol. 2013;131(3):351-357
引用
收藏
页码:351 / 357
页数:7
相关论文
共 37 条
  • [1] Web-based screening for diabetic retinopathy in a primary care population: The EyeCheck project
    Abramoff, MD
    Suttorp-Schulten, MSA
    [J]. TELEMEDICINE JOURNAL AND E-HEALTH, 2005, 11 (06): : 668 - 674
  • [2] Automated Early Detection of Diabetic Retinopathy
    Abramoff, Michael D.
    Reinhardt, Joseph M.
    Russell, Stephen R.
    Folk, James C.
    Mahajan, Vinit B.
    Niemeijer, Meindert
    Quellec, Gwenole
    [J]. OPHTHALMOLOGY, 2010, 117 (06) : 1147 - 1154
  • [3] Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes
    Abramoff, Michael D.
    Niemeijer, Meindert
    Suttorp-Schulten, Maria S. A.
    Viergever, Max A.
    Russell, Stephen R.
    van Ginneken, Bram
    [J]. DIABETES CARE, 2008, 31 (02) : 193 - 198
  • [4] The sensitivity and specificity of nonmydriatic digital stereoscopic retinal imaging in detecting diabetic retinopathy
    Ahmed, Jehanara
    Ward, Thomas P.
    Bursell, Sven-Eric
    Aiello, Lloyd M.
    Cavallerano, Jerry D.
    Vigersky, Robert A.
    [J]. DIABETES CARE, 2006, 29 (10) : 2205 - 2209
  • [5] DIAGNOSTIC-TESTS-3 - RECEIVER OPERATING CHARACTERISTIC PLOTS .7.
    ALTMAN, DG
    BLAND, JM
    [J]. BRITISH MEDICAL JOURNAL, 1994, 309 (6948) : 188 - 188
  • [6] [Anonymous], 1991, OPHTHALMOLOGY, V98, P823
  • [7] [Anonymous], 2008, NAT DIAB FACT SHEET
  • [8] [Anonymous], DIAB RET
  • [9] [Anonymous], NAT HLTH SERV DIAB R
  • [10] [Anonymous], U650 LATIMINSERM