Capillary electrochromatography with macroporous particles

被引:59
作者
Stol, R [1 ]
Kok, WT [1 ]
Poppe, H [1 ]
机构
[1] Univ Amsterdam, Dept Chem Engn, Analyt Chem Lab, NL-1018 WV Amsterdam, Netherlands
关键词
electrochromatography; stationary phases; LC; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(99)00384-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of macro-porous particles in capillary electrochromatography is studied. Three reversed-phase stationary phases with pore diameters between 500 Angstrom and 4000 Angstrom have been tested for separation efficiency and mobile phase velocity. With these stationary phases, a large portion of the total flow appears to be through the pores of particles, thereby increasing the separation efficiency through a further decrease of the how inhomogeneity and through enhancement of the mass transfer kinetics. The effects of pore size and mobile phase composition on the plate height and mobile phase velocity have been studied. With increasing buffer concentrations and larger pore diameters, higher mobile phase velocities and higher separation efficiencies have been obtained. Columns packed with 7 mu m particles containing pores with a diameter of 4000 Angstrom generated up to 430 000 theoretical plates/m for retained compounds. Reduced plate heights as low as 0.34 have been observed, clearly demonstrating that a significant portion of the flow is through the pores. For the particles containing 4000 Angstrom pores no minimum was observed in the H-u plot up to linear velocities of 3.3 mm/s, suggesting that the separation efficiency is dominated by axial diffusion. On relatively long (72 cm) columns, efficiencies of up to 230 000 theoretical plates/column have been obtained under non-optimal running conditions. On short (8.3 cm) columns fast separations could be performed with approximately 15 000 theoretical plates generated in less than 30 s. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 14 条
[11]   Experiences with packed capillary electrochromatography at ambient pressure [J].
vandenBosch, SE ;
Heemstra, S ;
Kraak, JC ;
Poppe, H .
JOURNAL OF CHROMATOGRAPHY A, 1996, 755 (02) :165-177
[12]   MASS-TRANSFER PHENOMENA IN GEL-PERMEATION CHROMATOGRAPHY [J].
VANKREVELD, ME ;
VANDENHOED, N .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :71-91
[13]  
VENEMA E, IN PRESS CHROMATOGRA
[14]   Capillary electrochromatography: effect of electrolyte concentration on electroosmotic flow and column efficiency [J].
Wan, QH .
JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (02) :181-189