Comparison of bipolar atrial electrogram amplitude in sinus rhythm, atrial fibrillation, and atrial flutter

被引:49
作者
Wood, MA [1 ]
Moskovljevic, P [1 ]
Stambler, BS [1 ]
Ellenbogen, KA [1 ]
机构
[1] HUNTER HOLMES MCGUIRE VET ADM MED CTR,RICHMOND,VA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1996年 / 19卷 / 02期
关键词
atrial fibrillation; atrial electrograms; mode switching;
D O I
10.1111/j.1540-8159.1996.tb03306.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automatic mode switching pacemakers revert to non-atrial tracking modes in response to sensed atrial tachyarrhythmias, It is unclear how atrial electrogram amplitudes in sinus rhythm compare to those during atrial tachyarrhythmias, In this study, peak-to-peak bipolar atrial electrogram amplitudes were measured during sinus rhythm and either atrial fibrillation or atrial flutter in 69 patients. The mean atrial electrogram amplitudes were 1.59 +/- 1.36 mV during sinus rhythm and 0.77 +/- 0.58 mV during atrial fibrillation (P < 0.0001) for 25 patients with atrial fibrillation and 1.81 +/- 2.07 mV during sinus and 1.5 +/- 1.81 mV (P < 0.0002) for 44 patients with atrial flutter. The mean electrogram amplitudes during both atrial fibrillation and flutter correlated significantly with amplitudes during sinus rhythm (R = 0.79, R = 0.94, respectively, both P < 0.0002). The coefficient of variance of individual electrogram amplitudes was greater in atrial fibrillation than sinus (P < 0.0002). By comparing 20th percentile electrogram amplitudes in atrial fibrillation and flutter to mean sinus amplitudes, intermittent very low electrogram amplitudes (< 0.3 mV) were more likely during atrial fibrillation and flutter if the mean sinus electrogram amplitudes were < 1.5 mV and < 0.5 mV, respectively (P < 0.01). Eightieth percentile electrogram amplitude values in atrial fibrillation and flutter were equally likely to exceed mean sinus amplitude values in respective patients. In conclusion, mean atrial electrogram amplitudes during atrial fibrillation and flutter are less than but correlated to sinus rhythm electrogram amplitudes. Very low amplitude individual electrograms during these atrial arrhythmias are associated with low mean sinus rhythm electrogram amplitudes. These findings may have implications for She programming of permanent dual chamber pacemakers in patients with paroxysmal atrial fibrillation and flutter.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 16 条
[1]  
ATTUEL P, 1988, PACE, V11, P1147
[2]   THE EFFECT OF DRUGS AND LEAD MATURATION ON ATRIAL ELECTROGRAMS DURING SINUS RHYTHM AND ATRIAL-FIBRILLATION [J].
BUMP, TE ;
RIPLEY, KL ;
GUEZENNEC, A ;
ARZBAECHER, R .
AMERICAN HEART JOURNAL, 1989, 117 (03) :577-584
[3]   TRACKING OF ATRIAL-FLUTTER DURING DDD PACING - ANOTHER FORM OF PACEMAKER-MEDIATED TACHYCARDIA [J].
GREENSPON, AJ ;
GREENBERG, RM ;
FRANKL, WS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06) :955-960
[4]   DDD PACING MODE SURVIVAL IN PATIENTS WITH A DUAL-CHAMBER PACEMAKER [J].
GROSS, JN ;
MOSER, S ;
BENEDEK, ZM ;
ANDREWS, C ;
FURMAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1536-1541
[5]   CHANGING EXPERIENCE WITH DUAL CHAMBER (DDD) PACEMAKERS [J].
HAYES, DL ;
HOLMES, DR ;
VLIETSTRA, RE ;
OSBORN, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (03) :556-559
[6]   DELETERIOUS EFFECTS OF LONG-TERM SINGLE-CHAMBER VENTRICULAR PACING IN PATIENTS WITH SICK SINUS SYNDROME - THE HIDDEN BENEFITS OF DUAL-CHAMBER PACING [J].
HESSELSON, AB ;
PARSONNET, V ;
BERNSTEIN, AD ;
BONAVITA, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1542-1549
[7]   ADVANTAGE OF DISCREPANT UPPER RATE LIMITS IN A DDDR PACEMAKER [J].
HIGANO, ST ;
HAYES, DL ;
EISINGER, G .
MAYO CLINIC PROCEEDINGS, 1989, 64 (08) :932-939
[8]   AMPLITUDE OF ATRIAL ELECTRICAL-ACTIVITY DURING SINUS RHYTHM AND DURING ATRIAL FLUTTER-FIBRILLATION [J].
KERR, CR ;
MASON, MA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03) :348-355
[9]   ATRIAL ARRHYTHMIA MANAGEMENT WITH SENSOR CONTROLLED ATRIAL REFRACTORY PERIOD AND AUTOMATIC-MODE SWITCHING IN PATIENTS WITH MINUTE VENTILATION SENSING DUAL CHAMBER RATE ADAPTIVE PACEMAKERS [J].
LAU, CP ;
TAI, YT ;
FONG, PC ;
LI, JPS ;
CHUNG, FLW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10) :1504-1514
[10]   A NEW FEATURE FOR CONTROL OF INAPPROPRIATE HIGH-RATE TRACKING IN DDDR PACEMAKERS [J].
LEE, MT ;
ADKINS, A ;
WOODSON, D ;
VANDEGRIFF, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12) :1852-1855