Cardiovascular circulation and hepatic perfusion of pigs in 4-dimensional films evaluated by 256-slice cone-beam computed tomography

被引:18
作者
Funabashi, N
Yoshida, K
Tadokoro, H
Nakagawa, K
Komiyama, N
Odaka, K
Tsunoo, T
Mori, S
Tanada, S
Endo, M
Komuro, I
机构
[1] Chiba Univ, Grad Sch Med, Dept Cardiovasc Sci & Med, Chuo Ku, Chiba 2608670, Japan
[2] Natl Inst Radiol Sci, Chiba, Japan
关键词
4-D perfusion cardiovascular circulation; hepatic perfusion; 256-slice cone beam computed tomography;
D O I
10.1253/circj.69.585
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In both cardiac and hepatic disorders it is desirable to accurately visualize the direction and scale of blood flow in the whole organ in pulsating 3-dimensional (D) images, which are known as 4-D images. Methods and Results The present study used 256-slice cone-beam computed tomography (CT) (Athena, Sony-Toshiba) at one rotation per second and a section thickness of 0.5 mm to show the dynamics of cardiovascular circulation and hepatic perfusion by contrast injection in 4-D films of pigs. Four pigs (20 kg each) were anesthetized with isoflurane. The distal tips of the catheters were positioned in the inferior vena cava (IVC) (pigs 1-3) and in the proper hepatic artery (pig 4). Volumetric scanning and injection of contrast material were started simultaneously and continued for 25s with image reconstruction at 1-s intervals. In pigs 1-3, 4-D filming revealed the dynamics of cardiovascular circulation, first in the IVC, followed by the right ventricle and pulmonary artery, then the left ventricle, left atrium, pulmonary vein, and finally, the right heart disappeared and only the left heart and aorta remained visible. In pig 4, the hepatic arterial trees, followed by the venous trees, could be easily visualized in turn on the 4-D images. Conclusions This technology successfully demonstrated cardiovascular circulation and hepatic perfusion in 4-D and will have clinical applicability.
引用
收藏
页码:585 / 589
页数:5
相关论文
共 28 条
[11]   Utility of three-dimensional volume rendering images using electron-beam computed tomography to evaluate possible causes of ischemia from an anomalous origin of the right coronary artery from the left sinus of Valsalva [J].
Funabashi, N ;
Kobayashi, Y ;
Rubin, GD .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (06) :575-578
[12]   Direct identification of patency achieved by a bi-directional Glenn shunt procedure - Images by volume rendering using electron-beam computed tomography [J].
Funabashi, N ;
Rubin, GD .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (05) :457-461
[13]  
Hirai T, 2004, AM J NEURORADIOL, V25, P74
[14]   CT screening: a trade-off of risks, benefits, and costs [J].
Hunink, MGM ;
Gazelle, GS .
JOURNAL OF CLINICAL INVESTIGATION, 2003, 111 (11) :1612-1619
[15]   Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging [J].
Inoue, T ;
Watanabe, S ;
Sakurada, H ;
Ono, K ;
Urano, M ;
Hijikata, Y ;
Saito, I ;
Masuda, Y .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (10) :760-764
[16]   Acute effects of diltiazem on regional left ventricular diastolic filling dynamics in patients with hypertrophic cardiomyopathy as assessed by color kinesis [J].
Ito, T ;
Suwa, M ;
Imai, M ;
Hozumi, T ;
Tonari, S ;
Kitaura, Y .
CIRCULATION JOURNAL, 2004, 68 (11) :1035-1040
[17]  
Kamiyama N, 2003, CIRC J, V67, P277
[18]   Coronary artery imaging with flat-panel computed tomography [J].
Knollmann, F ;
Pfoh, A .
CIRCULATION, 2003, 107 (08) :1209-1209
[19]  
LEITZ W, 1995, RADIAT PROT DOSIM, V57, P377
[20]   Effect of dobutamine on regional diastolic left ventricular asynchrony in patients with left ventricular hypertrophy - On-line quantification using automated segmental motion analysis system [J].
Liu, JY ;
Murata, K ;
Fujino, T ;
Ueda, K ;
Kimura, K ;
Wada, Y ;
Oyama, R ;
Tanaka, N ;
Matsuzaki, M .
CIRCULATION JOURNAL, 2003, 67 (02) :119-124