Tandem mass spectrometry in the clinical chemistry laboratory

被引:44
作者
Dooley, KC [1 ]
机构
[1] Dalhousie Univ, Sch Med, Dept Pathol, Halifax, NS, Canada
[2] Dalhousie Univ, Sch Med, Lab Med, IWK Hlth Ctr, Halifax, NS, Canada
关键词
D O I
10.1016/S0009-9120(03)00105-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Tandem mass spectrometry is becoming an increasingly important analytical technology in the clinical laboratory environment. Applications in toxicology and therapeutic drug monitoring have opened the door for tandem mass spectrometry and now we are seeing a vast array of new applications being developed. It has been the combination of tandem mass spectrometry with sample introduction techniques employing atomospheric pressure ionization that has enabled this technology to be readily implemented in the clinical laboratory. Although its major research applications started with pharmacology and proteomics, tandem mass spectrometry is being used for a great variety of analyses from steroids to catecholamines to peptides. As with chromatographic methods, tandem mass spectrometry is most cost effective when groups of compounds need to be measured simultaneously. However as the price/performance of this technology continues to improve. it will become even more widely utilized for clinical laboratory applications. (C) 2003 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:471 / 481
页数:11
相关论文
共 96 条
  • [51] 2-R
  • [52] Current developments in LC-MS for pharmaceutical analysis
    Lim, CK
    Lord, G
    [J]. BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (05) : 547 - 557
  • [53] Magera MJ, 2000, CLIN CHEM, V46, P1804
  • [54] Magera MJ, 1999, CLIN CHEM, V45, P1517
  • [55] MATHIAS W, 1996, ANAL CHEM, V68, P527
  • [56] Tandem mass spectrometry of protein-protein complexes:: Cytochrome c-cytochrome b5
    Mauk, MR
    Mauk, AG
    Chen, YL
    Douglas, DJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (01) : 59 - 71
  • [57] Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery
    Mei, H
    Hsieh, YS
    Nardo, C
    Xu, XY
    Wang, SY
    Ng, K
    Korfmacher, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) : 97 - 103
  • [58] Non-covalent associations of cyclomaltooligosaccharides (cyclodextrins) with carotenoids in water.: A study on the α- and β-cyclodextrin/ψ,ψ-carotene (lycopene) systems by light scattering, ionspray ionization and tandem mass spectrometry
    Mele, A
    Mendichi, R
    Selva, A
    Molnar, P
    Toth, G
    [J]. CARBOHYDRATE RESEARCH, 2002, 337 (12) : 1129 - 1136
  • [59] APPLICATION OF HIGH-RESOLUTION FAST ATOM BOMBARDMENT AND CONSTANT B-E RATIO LINKED SCANNING TO THE IDENTIFICATION AND ANALYSIS OF ACYLCARNITINES IN METABOLIC DISEASE
    MILLINGTON, DS
    ROE, CR
    MALTBY, DA
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1984, 11 (05): : 236 - 241
  • [60] A method for the quantitation of conjugated bile acids in dried blood spots using electrospray ionization-mass spectrometry
    Mills, KA
    Mushtaq, I
    Johnson, AW
    Whitfield, PD
    Clayton, PT
    [J]. PEDIATRIC RESEARCH, 1998, 43 (03) : 361 - 368