A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning

被引:14
作者
Ando, Masahiko [1 ,2 ]
Nishimura, Takashi [3 ]
Takewa, Yoshiaki [1 ]
Ogawa, Daisuke [6 ]
Yamazaki, Kenji [5 ]
Kashiwa, Koichi [4 ]
Kyo, Shunei [3 ]
Ono, Minoru [2 ]
Taenaka, Yoshiyuki [1 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cardiovasc Ctr, Dept Artificial Organ, Res Inst, Osaka 5658565, Japan
[2] Univ Tokyo, Dept Cardiothorac Surg, Bunkyo Ku, Tokyo 1138655, Japan
[3] Univ Tokyo, Dept Therapeut Strategy Heart Failure, Bunkyo Ku, Tokyo 1138655, Japan
[4] Tokyo Univ Hosp, Dept Med Engn, Bunkyo Ku, Tokyo 1138655, Japan
[5] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, Tokyo 1628666, Japan
[6] Sun Med Technol Res Corp, Nagano 3920012, Japan
关键词
Left ventricular assist device; Bridge to recovery; Mock circulation; HEART-FAILURE; SAFETY; SYSTEM;
D O I
10.1007/s10047-010-0544-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent developments in adjunct therapeutic options for end-stage heart failure have enabled us to remove implanted left ventricular assist devices (LVADs) from more patients than before. However, a safe and proper protocol for pump-off trials is yet to be established, because diastolic backward flow in a pump circuit turns up when it is driven at low-flow conditions. We have developed a novel drive mode of centrifugal pumps that can change its rotational speed in synchronization with the cardiac cycle of the native heart. The purpose of this study was to test-drive this novel system of a centrifugal pump in a mock circulation and to evaluate the effect of the counterpulse mode, which increases pump speed just in diastole, on the amount of this nonphysiological intracircuit retrograde flow. A rotary pump (EVAHEART, Sun Medical Technology Research Corporation) was connected to the mock circulation by left ventricular uptake and ascending aortic return. We drove it in the following four conditions: (A) continuous mode at 1500 rpm, (B) counterpulse mode (systolic 1500 rpm, diastolic 2500 rpm), (C) continuous mode at 2000 rpm, and (D) counterpulse mode (systolic 2000 rpm, diastolic 2500 rpm). Data concerning the rotation speed, pump flow, left ventricular pressure, aortic pressure, and pressure head (i.e., aortic pressure-left ventricular pressure) in each condition were collected. After data collection, we analyzed pump flow, and calculated its forward and backward flow. Counterpulse mode decreased the amounts of pump backward flow compared with the continuous mode [mean backward flow, -4, -1, -0.5, 0 l/min, in (A), (B), (C), and (D) conditions, respectively]. The actual amounts of mean backward flow can be different from those in clinical situations; however, this novel drive mode for rotary pumps can relatively decrease pump backward flow during pump weaning and can be beneficial for safe and proper pump-off trials. Further investigations in in vivo settings are currently ongoing.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 9 条
[1]   Left ventricular assist device and drug therapy for the reversal of heart failure [J].
Birks, Emma J. ;
Tansley, Patrick D. ;
Hardy, James ;
George, Robert S. ;
Bowles, Christopher T. ;
Burke, Margaret ;
Banner, Nicholas R. ;
Khaghani, Asghar ;
Yacoub, Magdi H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) :1873-1884
[2]   Prediction of cardiac stability after weaning from left ventricular assist devices in patients with idiopathic dilated cardiomyopathy [J].
Dandel, Michael ;
Weng, Yuguo ;
Siniawski, Henryk ;
Potapov, Evgenij ;
Drews, Thorsten ;
Lehmkuhl, Hans B. ;
Knosalla, Christoph ;
Hetzer, Roland .
CIRCULATION, 2008, 118 (14) :S94-S105
[3]   Which factors predict the recovery of natural heart function after insertion of a left ventricular assist system? [J].
Mano, A. ;
Nakatani, T. ;
Oda, N. ;
Kato, T. ;
Niwaya, K. ;
Tagusari, O. ;
Nakajima, H. ;
Funatsu, T. ;
Hashimoto, S. ;
Komamura, K. ;
Hanatani, A. ;
Ueda, I. H. ;
Kitakaze, M. ;
Kobayashi, J. ;
Yagihara, T. ;
Kitamura, S. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (08) :869-874
[4]   Hemodynamics and patient safety during pump-off studies of an axial-flow left ventricular assist device [J].
Myers, TJ ;
Frazier, OH ;
Mesina, HS ;
Radovancevic, B ;
Gregoric, ID .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (04) :379-383
[5]   Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device [J].
Slaughter, Mark S. ;
Rogers, Joseph G. ;
Milano, Carmelo A. ;
Russell, Stuart D. ;
Conte, John V. ;
Feldman, David ;
Sun, Benjamin ;
Tatooles, Antone J. ;
Delgado, Reynolds M., III ;
Long, James W. ;
Wozniak, Thomas C. ;
Ghumman, Waqas ;
Farrar, David J. ;
Frazier, O. Howard .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2241-2251
[6]   The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: In vitro test [J].
Tayama, E ;
Ohashi, Y ;
Niimi, Y ;
Takami, Y ;
Ohtsuka, G ;
Nakata, K ;
Benkowski, R ;
Glueck, JA ;
Nose, Y .
ARTIFICIAL ORGANS, 1998, 22 (04) :342-345
[7]   INTRAAORTIC BALLOON COUNTERPULSATION - REVIEW OF PHYSIOLOGICAL PRINCIPLES, CLINICAL RESULTS, AND DEVICE SAFETY [J].
WEBER, KT ;
JANICKI, JS .
ANNALS OF THORACIC SURGERY, 1974, 17 (06) :602-636
[8]   EVAHEART™: An implantable centrifugal blood pump for long-term circulatory support [J].
Kenji Yamazaki ;
Shinichiro Kihara ;
Takehide Akimoto ;
Osamu Tagusari ;
Akihiko Kawai ;
Mitsuo Umezu ;
Jun Tomioka ;
Robert L. Kormos ;
Bartley P. Griffith ;
Hiromi Kurosawa .
The Japanese Journal of Thoracic and Cardiovascular Surgery, 2002, 50 (11) :461-465
[9]   Completely pulsatile high flow circulatory support with a constant-speed centrifugal blood pump: mechanisms and early clinical observations. [J].
Yamazaki K. ;
Saito S. ;
Kihara S. ;
Tagusari O. ;
Kurosawa H. .
General Thoracic and Cardiovascular Surgery, 2007, 55 (4) :158-162