Adaptive imaging and spatial compounding in the presence of aberration

被引:41
作者
Dahl, JJ [1 ]
Guenther, DA
Trahey, GE
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Radiol, Durham, NC 27706 USA
关键词
D O I
10.1109/TUFFC.2005.1503999
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Spatial compounding reduces speckle and increases image contrast by incoherently averaging images acquired at different viewing angles. Adaptive imaging improves contrast and resolution by compensating for tissue-induced phase errors. Aberrator strength and spatial frequency content markedly impact the desirable operating characteristics and performance of these methods for improving image quality. Adaptive imaging, receive-spatial compounding, and a combination of these two methods are presented in contrast and resolution tasks under various aberration characteristics. All three imaging methods yield increases in the contrast-to-noise ratio (CNR) of anechoic cysts; however, the improvements vary depending on the properties of the aberrating layer. Phase correction restores image spatial frequencies, and the addition of compounding opposes the restoration of image spatial frequencies. Lesion signal-to-noise ratio (SNR), an image quality metric for predicting lesion detectability, shows that combining spatial compounding with phase correction yields the maximum detectability when the aberrator strength or spatial frequency content is high. Examples of these modes are presented in thyroid tissue.
引用
收藏
页码:1131 / 1144
页数:14
相关论文
共 35 条
[1]  
Dahl JJ, 2003, ULTRASON, P1532
[2]   Performance evaluation of spatial compounding in the presence of aberration and adaptive Imaging [J].
Dahl, JJ ;
Guenther, D ;
Trahey, GE .
MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 :1-11
[3]  
Fernandez AT, 2001, ULTRASON, P1489, DOI 10.1109/ULTSYM.2001.992002
[4]   TIME-REVERSAL OF ULTRASONIC FIELDS .1. BASIC PRINCIPLES [J].
FINK, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) :555-566
[5]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767
[6]   Wavefront estimation in the human breast [J].
Gauss, RC ;
Trahey, GE ;
Soo, MS .
MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2001, 4325 :172-181
[7]  
GAUSS RC, 2003, THESIS DUKE U DURHAM
[8]  
Goodman J., 2000, Statistical Optics
[9]   MEASUREMENT AND CORRECTION OF ULTRASONIC PULSE DISTORTION PRODUCED BY THE HUMAN BREAST [J].
HINKELMAN, LM ;
LIU, DL ;
WAAG, RC ;
ZHU, Q ;
STEINBERG, BD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1958-1969
[10]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351