Evaluation of imaging geometries calculated from biplane images

被引:10
作者
Esthappan, J
Harauchi, H
Hoffmann, KR
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
[2] Osaka Univ, Fac Med, Sch Allied Hlth Sci, Osaka 5650871, Japan
关键词
3D reconstruction; biplane; imaging geometry;
D O I
10.1118/1.598275
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique is developed that will calculate accurate and reliable imaging geometries and three-dimensional (3D) positions from biplane images of a calibration phantom. The calculated data provided by our technique will facilitate accurate 3D analysis in various clinical applications. Biplane images of a Lucite cube containing lead beads 1 mm in diameter were acquired. After identifying corresponding beads in both images and calculating their image positions, the 3D positions of the beads relative to each focal spot were determined. From these data, the transformation relating the 3D configurations were calculated to give the imaging geometry relating the biplane views. The 3D positions of objects were determined from the biplane images along with the corresponding imaging geometries. In addition, methods are developed to evaluate the quality of the calculated results on a case-by-case basis in the clinical setting. Methods are presented for evaluating the reproducibility of the calculated geometries and 3D positions, the accuracy of calculated object sizes, and the effects of errors due to time jitter, variation in user-indication, centering, and distortions on the calculated geometries and 3D reconstructions. The precision of the translation vectors and rotation matrices of the calculated geometries were within 1% and 1 degrees, respectively, in phantom studies, with estimated accuracies of approximately 0.5% and 0.4 degrees, respectively, in simulation studies. The precisions of the absolute 3D positions and orientations of the calculated 3D reconstructions were approximately 2 mm and 0.5 degrees, respectively, in phantom studies, with estimated accuracies of approximately 1.5 mm and 0.4 degrees, respectively, in simulation studies. This technique will provide accurate and precise imaging geometries as well as 3D positions from biplane images, thereby facilitating 3D analysis in various clinical applications. We believe that the study presented here is unique in that it represents the first steps toward understanding and evaluating the reliability of these 3D calculations in the clinical situation. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01606-X].
引用
收藏
页码:965 / 975
页数:11
相关论文
共 32 条
  • [11] Determination of three-dimensional positions of known sparse objects from a single projection
    Hoffmann, KR
    Esthappan, J
    [J]. MEDICAL PHYSICS, 1997, 24 (04) : 555 - 564
  • [12] DETERMINATION OF 3D IMAGING GEOMETRY AND OBJECT CONFIGURATIONS FROM 2 BIPLANE VIEWS - AN ENHANCEMENT OF THE METZ-FENCIL TECHNIQUE
    HOFFMANN, KR
    METZ, CE
    CHEN, Y
    [J]. MEDICAL PHYSICS, 1995, 22 (08) : 1219 - 1227
  • [13] Determination of 3D positions of pacemaker leads from biplane angiographic sequences
    Hoffmann, KR
    Williams, BB
    Esthappan, J
    Chen, SYJ
    Carroll, JD
    Harauchi, H
    Doerr, V
    Kay, GN
    Eberhardt, A
    Overland, M
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1854 - 1862
  • [14] A simple technique for calibrating imaging geometries
    Hoffmann, KR
    Esthappan, J
    Li, SD
    Pelizzari, CA
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 371 - 376
  • [15] Pincushion correction techniques and their effects on calculated 3D positions and imaging geometries
    Hoffmann, KR
    Chen, Y
    Esthappan, J
    Chen, SY
    Carroll, JD
    [J]. MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 462 - 467
  • [16] HOFFMANN KR, 1996, IEEE COMPUTERS CARDI, P113
  • [17] SEMIAUTOMATED MATCHING AND SEED POSITION LOCATION FOR IMPLANTED RIBBONS
    KASSAEE, A
    ALTSCHULER, MD
    [J]. MEDICAL PHYSICS, 1994, 21 (05) : 643 - 650
  • [18] MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS
    KELLER, PJ
    DRAYER, BP
    FRAM, EK
    WILLIAMS, KD
    DUMOULIN, CL
    SOUZA, SP
    [J]. RADIOLOGY, 1989, 173 (02) : 527 - 532
  • [19] New source localization algorithm with no requirement of one-to-one source correspondence between biplane radiographs
    Li, S
    Chen, GTY
    Pelizzari, CA
    Reft, C
    Roeske, JC
    Lu, Y
    [J]. MEDICAL PHYSICS, 1996, 23 (06) : 921 - 927
  • [20] GRAPHICS METHODS FOR TRACKING 3-DIMENSIONAL HEART WALL MOTION
    MACKAY, SA
    POTEL, MJ
    RUBIN, JM
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1982, 15 (05): : 455 - 473