A new imaging modality for intraoperative evaluation of sinus floor augmentation

被引:11
作者
Blake, F. A. S. [1 ]
Blessmann, M. [1 ]
Pohlenz, P. [1 ]
Heiland, M. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
关键词
D O I
10.1016/j.ijom.2007.09.174
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this report was to demonstrate the practicability of anew imaging modality, which allows three-dimensional intraoperative imaging and verification of bone-graft position, and to compare it to the currently available imaging systems. The ARCADIS Orbic 3D, a C-arm-based cone-beam computed tomography scanner developed for intraoperative imaging, was used to examine a previously augmented sinus floor, in order to verify the height and width of the augmentation and to determine whether any of the autogenous and synthetic bone-substitute mixture had penetrated the sinus membrane. Visualization of the entire sinus was possible with the aid of multiplanar reconstructions. Data acquisition and processing took 5 min.
引用
收藏
页码:183 / 185
页数:3
相关论文
共 12 条
[1]   Sinus lift procedure of the maxilla in patients with inadequate bone for dental implants: Radiographic appearance [J].
Abrahams, JJ ;
Hayt, MW ;
Rock, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1289-1292
[2]  
Aimetti M, 2001, INT J PERIODONT REST, V21, P581
[3]  
BOYNE PJ, 1980, J ORAL SURG, V38, P613
[4]   Assessment of maxillary sinus volume for the sinus lift operation by three-dimensional magnetic resonance imaging [J].
Gray, CF ;
Staff, RT ;
Redpath, TW ;
Needham, G ;
Renny, NMP .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (03) :154-158
[5]   Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system [J].
Heiland, M ;
Schulze, D ;
Blake, F ;
Schmelzle, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (04) :369-375
[6]   3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D) [J].
Heiland, M ;
Schulze, D ;
Adam, G ;
Schmelzle, R .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) :21-25
[7]  
KUNKEL M, 2003, ZAHNARZTL MITT, V93, P52
[8]  
Salib RJ, 2001, J LARYNGOL OTOL, V115, P676
[9]   Radiation exposure during midfacial imaging using 4-and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography [J].
Schulze, D ;
Heiland, M ;
Thurmann, H ;
Adam, G .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (02) :83-86
[10]   Sinus-lift graft: Using the maxillary sinuses to support implants [J].
Small, SA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1996, 127 (01) :51-57