Considerations for the implementation of target volume protocols in radiation therapy

被引:31
作者
Craig, T
Battista, J
Moiseenko, V
Van Dyk, J
机构
[1] London Reg Canc Ctr, Dept Phys, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 49卷 / 01期
基金
英国医学研究理事会;
关键词
planning target volume; patient repositioning; organ motion; geometric uncertainty; margins;
D O I
10.1016/S0360-3016(00)01354-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Uncertainties in patient repositioning and organ motion are accounted for by defining a planning target volume (PTV). We make recommendations on issues not explicitly discussed in existing protocols for PTV design. Methods: A quantity called "coverage" is defined to quantify how effectively a PTV encompasses the clinical target volume, and is applied to examine the impact of several factors, A stochastic simulation is used to determine the coverage required for a desirable balance between tumor control probability (TCP) and the irradiated volume. Using a sample anatomy, we assess the importance of the method used to add uncertainties, the shape of the uncertainty distribution, the effect of systematic uncertainties, and the use of nonuniform margins. Additionally, we examine the benefit of patient immobilization techniques. Results: Our example indicates that 95% coverage is a reasonable goal for treatment planning. Using this as a comparison value, our example indicates quadrature addition of uncertainties predicts smaller margins (7 mm) than linear addition (11 mm), Gaussian distribution of uncertainties (7 mm) require the same margin as a uniform distribution (7 mm), systematic uncertainties have a small effect on TCP below a threshold value (4 mm), and nonuniform margins allow only a slight reduction of irradiated volume. Conclusion: We recommend that uncertainties should generally be added in quadrature, the exact shape of the uncertainty distribution is not critical, systematic uncertainties should be maintained below some threshold value, and nonuniform margins may be effective when uncertainties are anisotropic, (C) 2001 Elsevier Science Inc.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 23 条
[1]  
AALTONEN P, 1997, ACTA ONCOL S, V10, P1
[2]   Planning target volumes for radiotherapy: How much margin is needed? [J].
Antolak, JA ;
Rosen, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1165-1170
[3]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[4]  
BEDFORD J, 1988, MED PHYS, V25, P224
[5]   THE EFFECTIVENESS OF IMMOBILIZATION DURING PROSTATE IRRADIATION [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP ;
ANSCHER, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :143-148
[6]   What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? [J].
Ekberg, L ;
Holmberg, O ;
Wittgren, L ;
Bjelkengren, G ;
Landberg, T .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) :71-77
[7]   Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer [J].
Fiorino, C ;
Reni, M ;
Bolognesi, A ;
Bonini, A ;
Cattaneo, GM ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (02) :133-141
[8]   Implications of 3-dimensional target shape and motion in aperture design [J].
Fontenla, E ;
Pelizzari, CA ;
Chen, GTY .
MEDICAL PHYSICS, 1996, 23 (08) :1431-1441
[9]  
International Commission in Radiation Units and Measurements, 1999, 62 ICRU
[10]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU