Lower limb angiography: A prospective study comparing carbon dioxide with iodinated contrast material in 30 patients

被引:40
作者
Rolland, Y
Duvauferrier, R
Lucas, A
Gourlay, C
Morcet, N
Rambeau, M
Chaperon, J
机构
[1] Hop Sud, Dept Radiol, F-35000 Rennes, France
[2] Hop Sud, Dept Vasc Surg, F-35000 Rennes, France
[3] Hop Pontchaillou, Dept Stat, Rennes, France
关键词
D O I
10.2214/ajr.171.2.9694446
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We prospectively compared patients' tolerance for and the usefulness of carbon dioxide (CO2) with iodinated contrast material in the study of lower limb arteries in 30 patients. SUBJECTS AND METHODS. We systematically performed digital subtraction angiography with electronic injection of CO2 (injection average, 330 ml) and digital subtraction angiography with iodinated contrast material in 30 patients (20 men and 10 women; mean age, 67.5 years) suffering from lower limb ischemia. Patients were monitored for vital signs and comfort. Four reviewers subjectively evaluated vessel visibility at five levels (pelvis, thigh, knee, calf, and ankle). We used the Student's t test to evaluate the tolerance and the global examination quality. The chi-square test was used to evaluate the stratified analysis of the observers and scores of the image quality according to the anatomic level studied. Bartlett's test of equality of variances was used to compare the variances between the readers. RESULTS, CO2 was less well tolerated (p <.01) than iodine was. Fifty-three percent of patients reported CO2 was equally well tolerated (53%), 40% reported more discomfort than with iodine, and 4% reported less discomfort than with iodine. Both techniques were equivalent for imaging of the iliac arteries, but CO2 performed poorly in the arteries below the knee (p <<.001). CONCLUSION. CO2 angiography with electronic injection proved to be less comfortable than iodinated angiography. CO2 arteriography is equivalent to iodinated arteriography for imaging the iliac arteries but imaging performance progressively degrades in the more distal arteries of the legs.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 21 条
[1]  
BENDIB M, 1977, ANN RADIOL, V20, P673
[2]   CARBON-DIOXIDE AS AN ANGIOGRAPHIC CONTRAST AGENT - A PROSPECTIVE RANDOMIZED TRIAL [J].
BETTMANN, MA ;
DAGOSTINO, R ;
JURAVSKY, LI ;
JEFFERY, RF ;
TOTTLE, A ;
GOUDEY, CP .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S45-S46
[3]  
BRIEND R, 1995, Patent No. 5427104
[4]   THE CEREBROVASCULAR EFFECTS OF INTRAARTERIAL CO2 IN QUANTITIES REQUIRED FOR DIAGNOSTIC-IMAGING [J].
COFFEY, R ;
QUISLING, RG ;
MICKLE, JP ;
HAWKINS, IF ;
BALLINGER, WB .
RADIOLOGY, 1984, 151 (02) :405-410
[5]  
FERMAND M, 1994, PRESSE MED, V23, P19
[6]   SHORT-TERM EFFECTS OF SELECTIVE RENAL ARTERIAL CARBON-DIOXIDE ADMINISTRATION ON THE DOG KIDNEY [J].
HAWKINS, IF ;
MLADINICH, CRJ ;
STORM, B ;
CROKER, BP ;
WILCOX, CS ;
AKINS, EW ;
DRAKE, W .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (01) :149-154
[7]  
HAWKINS IF, 1982, AM J ROENTGENOL, V139, P19, DOI 10.2214/ajr.139.1.19
[8]  
KERNS SR, 1995, RADIOL CLIN N AM, V33, P15
[9]   CARBON-DIOXIDE DIGITAL SUBTRACTION ANGIOGRAPHY - EXPANDING APPLICATIONS AND TECHNICAL EVOLUTION [J].
KERNS, SR ;
HAWKINS, IF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) :735-741
[10]   CO2-ANGIOGRAPHY - MEASUREMENT OF VASCULAR GAS-FILLING AND EVALUATION OF PARAMETERS INFLUENCING GAS INJECTION USING A CIRCULATORY-SYSTEM MODEL [J].
KONIG, T ;
KRASNY, R .
BIOMEDIZINISCHE TECHNIK, 1991, 36 (11) :266-270