CARBON-DIOXIDE DIGITAL SUBTRACTION ANGIOGRAPHY - EXPANDING APPLICATIONS AND TECHNICAL EVOLUTION

被引:119
作者
KERNS, SR
HAWKINS, IF
机构
[1] Department of Radiology, University of Florida, JHMHC, Gainesville
关键词
D O I
10.2214/ajr.164.3.7863904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although several noninvasive techniques now exist far vascular imaging, including MR imaging, three-dimensional CT, and color-flow and duplex sonography, the gold standard to which these techniques are compared remains catheter angiography. Cut-film and digital subtraction angiography (DSA) using iodinated contrast material are the standard methods by which vascular imaging is performed. However, despite the development of low-osmolar contrast agents, premedication regimens, and careful patient selection, adverse reactions to contrast material, including idiosyncratic reactions and contrast-induced nephropathy, continue to occur in a small number of patients [1-3]. Carbon dioxide (CO2) was developed as an alternative to iodinated contrast material to avoid these problems [4], Once the behavior of intravascular gas, the methods of safe delivery, and the principles of successful imaging are understood, the use of CO2 as an intravascular contrast agent during DSA allows accurate imaging with little risk. Recent advances in delivery systems, postprocessing capabilities, and its extension to new vascular interventional procedures have greatly expanded the usefulness of COP angiography in both diagnostic and interventional vascular radiology.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 27 条
[1]   METAANALYSIS OF THE RELATIVE NEPHROTOXICITY OF HIGH-OSMOLALITY AND LOW-OSMOLALITY IODINATED CONTRAST-MEDIA [J].
BARRETT, BJ ;
CARLISLE, EJ .
RADIOLOGY, 1993, 188 (01) :171-178
[2]   RENEWED INTEREST IN GASES FOR CONTRAST ROENTGENOGRAPHY [J].
BURKO, H ;
KLATTE, EC .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1967, 99 (03) :645-&
[3]   THE CEREBROVASCULAR EFFECTS OF INTRAARTERIAL CO2 IN QUANTITIES REQUIRED FOR DIAGNOSTIC-IMAGING [J].
COFFEY, R ;
QUISLING, RG ;
MICKLE, JP ;
HAWKINS, IF ;
BALLINGER, WB .
RADIOLOGY, 1984, 151 (02) :405-410
[4]   SAFETY OF INTRAVASCULAR CARBON DIOXIDE AND ITS USE FOR ROENTGENOLOGIC VISUALIZATION OF INTRACARDIAC STRUCTURES [J].
DURANT, TM ;
STAUFFER, HM ;
OPPENHEIMER, MJ ;
PAUL, RE .
ANNALS OF INTERNAL MEDICINE, 1957, 47 (02) :191-201
[5]  
GOLDENBERG DB, 1967, MARYLAND STATE MED J, V17, P79
[6]   THE PREVENTION OF IMMEDIATE GENERALIZED REACTIONS TO RADIOCONTRAST MEDIA IN HIGH-RISK PATIENTS [J].
GREENBERGER, PA ;
PATTERSON, R .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1991, 87 (04) :867-872
[7]   FOLLOW-UP EVALUATION AFTER RENAL-ARTERY BYPASS-SURGERY WITH USE OF CARBON-DIOXIDE ARTERIOGRAPHY AND COLOR-FLOW DUPLEX SCANNING [J].
HARWARD, TRS ;
SMITH, S ;
HAWKINS, IF ;
SEEGER, JM .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) :23-30
[8]   SHORT-TERM EFFECTS OF SELECTIVE RENAL ARTERIAL CARBON-DIOXIDE ADMINISTRATION ON THE DOG KIDNEY [J].
HAWKINS, IF ;
MLADINICH, CRJ ;
STORM, B ;
CROKER, BP ;
WILCOX, CS ;
AKINS, EW ;
DRAKE, W .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (01) :149-154
[9]  
HAWKINS IF, 1982, AM J ROENTGENOL, V139, P19, DOI 10.2214/ajr.139.1.19
[10]  
HAWKINS IF, 1994, CURRENT TECHNIQUES I