Three-dimensional ultrasound-based navigation combined with preoperative CT during abdominal interventions:: A feasibility study

被引:40
作者
Kaspersen, JH [1 ]
Sjolie, E
Wesche, J
Åsland, J
Lundbom, J
Odegåord, A
Lindseth, F
Hernes, TAN
机构
[1] SINTEF Unimed, Dept Ultrasound, N-7465 Trondheim, Norway
[2] Univ Trondheim Hosp, Vasc Dept, N-7465 Trondheim, Norway
[3] Univ Trondheim Hosp, Dept Radiol, N-7465 Trondheim, Norway
关键词
3D ultrasound; navigation; abdominal interventions; preoperative data;
D O I
10.1007/s00270-003-2690-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Three-dimensional (3D) intraoperative ultrasound may be easier to interpret when used in combination with less noisy preoperative image data such as CT. The purpose of this study was to evaluate the use of preoperative image data in a 3D ultrasound-based navigation system specially designed for minimally invasive abdominal surgery. A prototype system has been tested in patients with aortic aneurysms undergoing clinical assessment before and after abdominal aortic stent-graft implantation. Methods: All patients were first imaged by spiral CT followed by 3D ultrasound scanning. The CT volume was registered to the patient using fiducial markers. This enabled us to compare corresponding slices from 3D ultrasound and CT volumes. The accuracy of the patient registration was evaluated both using the external fiducial markers (artificial landmarks glued on the patient's skin) and using intraoperative 3D ultrasound as a measure of the true positioning of anatomic landmarks inside the body. Results: The mean registration accuracy on the surface was found to be 7.1 mm, but increased to 13.0 mm for specific landmarks inside the body. CT and ultrasound gave supplementary information of surrounding structures and position of the patient's anatomy. Fine-tuning the initial patient registration of the CT data with a multimodal CT to intraoperative 3D ultrasound registration (e.g., mutual information), as well as ensuring no movements between this registration and image guidance, may improve the registration accuracy. Conclusion: Preoperative CT in combination with 3D ultrasound might be helpful for guiding minimal invasive abdominal interventions.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 26 条
[1]   Variability and accuracy of measurements of prostate brachytherapy seed position in vitro using three-dimensional ultrasound:: An intra- and inter-observer study [J].
Blake, CC ;
Elliot, TL ;
Slomka, PJ ;
Downey, DB ;
Fenster, A .
MEDICAL PHYSICS, 2000, 27 (12) :2788-2795
[2]   An algorithm for automatic needle localization in ultrasound-guided breast biopsies [J].
Draper, KJ ;
Blake, CC ;
Gowman, L ;
Downey, DB ;
Fenster, A .
MEDICAL PHYSICS, 2000, 27 (08) :1971-1979
[3]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[4]   SonoWand, an ultrasound-based neuronavigation system [J].
Gronningsaeter, A ;
Kleven, A ;
Ommedal, S ;
Aarseth, TE ;
Lie, T ;
Lindseth, F ;
Lango, T ;
Unsgard, G .
NEUROSURGERY, 2000, 47 (06) :1373-1379
[5]  
Grunert P, 1998, Comput Aided Surg, V3, P166, DOI 10.1002/(SICI)1097-0150(1998)3:4<166::AID-IGS6>3.3.CO
[6]  
2-5
[7]   Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration [J].
Hata, N ;
Dohi, T ;
Iseki, H ;
Takakura, K .
NEUROSURGERY, 1997, 41 (03) :608-613
[8]   Intraoperative three-dimensional ultrasonography: An approach to register brain shift using multidimensional image processing [J].
Jodicke, A ;
Deinsberger, W ;
Erbe, H ;
Kriete, A ;
Boker, DK .
MINIMALLY INVASIVE NEUROSURGERY, 1998, 41 (01) :13-19
[9]  
LINDSETH F, 2003, IN PRESS J ULTRASOUN
[10]  
LINDSETH F, 2001, P COMPUTER ASSISTED, P247