Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration

被引:108
作者
Hata, N
Dohi, T
Iseki, H
Takakura, K
机构
[1] UNIV TOKYO, FAC ENGN, DEPT PRECIS MACHINERY ENGN, TOKYO 113, JAPAN
[2] TOKYO WOMENS MED COLL, NEUROL INST, DEPT NEUROSURG, TOKYO 162, JAPAN
关键词
computer-assisted surgery; frameless stereotaxy; neuronavigation; three-dimensional reconstruction; ultrasonography; SURGERY; BRAIN; LOCALIZATION; WAND;
D O I
10.1097/00006123-199709000-00020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: We have developed a frameless stereotactic neuronavigation system that allows navigation during neurosurgical procedures through an image formed from integrating ultrasonography and preoperative magnetic resonance (MR) imaging and/or x-ray computed tomography. METHODS: The system consists of an ultrasound imaging scanner, a workstation with an image capture board, and an ultrasonic tracking sensor with a 5-MHz ultrasonographic transducer. The ultrasonic tracking sensor measures the position and orientation of the ultrasonographic transducer. The oblique plane of the MR/computed tomographic image corresponding to the ultrasound image is then displayed on the workstation monitor. A three-dimensional computer graphic representation of the integrated image is also reported as a preliminary test. For the patient-image registration, the coordinates of digitized and imaged markers on a specially developed reference frame are used, The reference frame is noninvasive because it is not bolted but only fastened to the patient's head with silicon. RESULTS: Based on the findings from the clinical application of the system in three cases, the system was advantageous because the surgical procedures could be controlled by intraoperative ultrasonography as well as by preoperative MR/computed tomographic images. Missing parts in the ultrasonogram were supplemented with preoperative MR/computed tomographic images. At other times, spatial positioning and visualization by ultrasonography were useful for identifying anatomical objects in the image, CONCLUSION: This preliminary study of the frameless integration of ultrasonography into stereotactic space demonstrated its clinical usefulness. We believe that the concept of pre-and intraoperative image-guided surgery presented here will find increasing use in the future.
引用
收藏
页码:608 / 613
页数:6
相关论文
共 18 条
  • [1] USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING
    BARNETT, GH
    KORMOS, DW
    STEINER, CP
    WEISENBERGER, J
    [J]. NEUROSURGERY, 1993, 33 (04) : 674 - 678
  • [2] INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE
    BARNETT, GH
    KORMOS, DW
    STEINER, CP
    WEISENBERGER, J
    [J]. JOURNAL OF NEUROSURGERY, 1993, 78 (03) : 510 - 514
  • [3] ULTRASOUND-GUIDED STEREOTAXIC BIOPSY USING A NEW APPARATUS
    BERGER, MS
    [J]. JOURNAL OF NEUROSURGERY, 1986, 65 (04) : 550 - 554
  • [4] HASHIMOTO D, 1991, SURGERY, V109, P589
  • [5] Hata Nobuhiko., 1994, Visualization in Biomedical Computing 1994, V2359, P251
  • [6] ISEKI H, 1994, STEREOT FUNCT NEUROS, V63, P130, DOI 10.1159/000100304
  • [7] JIANG HJ, 1992, P SOC PHOTO-OPT INS, V1808, P196, DOI 10.1117/12.131078
  • [8] A FRAMELESS, ARMLESS NAVIGATIONAL SYSTEM FOR COMPUTER-ASSISTED NEUROSURGERY
    KATO, A
    YOSHIMINE, T
    HAYAKAWA, T
    TOMITA, Y
    IKEDA, T
    MITOMO, M
    HARADA, K
    MOGAMI, H
    [J]. JOURNAL OF NEUROSURGERY, 1991, 74 (05) : 845 - 849
  • [9] Kelly PJ, 1991, TUMOR STEREOTAXIS
  • [10] ULTRASOUND-CONTROLLED NEURONAVIGATOR-GUIDED BRAIN SURGERY
    KOIVUKANGAS, J
    LOUHISALMI, Y
    ALAKUIJALA, J
    OIKARINEN, J
    [J]. JOURNAL OF NEUROSURGERY, 1993, 79 (01) : 36 - 42