INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE

被引:145
作者
BARNETT, GH
KORMOS, DW
STEINER, CP
WEISENBERGER, J
机构
[1] Department of Neurosurgery, Cleveland Clinic Foundation, 1 Clinic Center, Cleveland
关键词
STEREOTAXIS; OPERATIVE TECHNIQUE; INSTRUMENTATION;
D O I
10.3171/jns.1993.78.3.0510
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A technique of ''frameless'' stereotaxy that allows real-time intraoperative neurosurgical localization is described. The system is composed of four components: a hand-held probe containing two ultrasonic emitters. a microphone array that is rigidly affixed to the operating table in proximity to the surgical field, hardware to control and detect timing of signal production and reception, and a color graphics computer workstation with software to calculate and present the location of the probe tip on reconstructed neuroimaging studies. Unlike previously reported mechanical or sonic navigational devices, this system is adaptable to a wide array of neurosurgical instruments, allows free movement of the operating table and conventional patient draping, and has accuracy in the hostile operating room environment that rivals that of frame stereotaxy. In the operating room environment, using four pulse pairs with the wand positioned optimally, reproducibility of a point in space is +/- 0.6 mm. The wand has a broad range of orientations that maintain error at or below 1.0 mm. The mean error when measuring distances within a 1000-cu cm cube is 1.1 +/- 1.0 mm (1.0% +/- 0.7%). The ability to localize a fourth point (a target) in space is typically within 1.5 mm (using computerized tomography scans with a 1-mm slice thickness) but is dependent on several variables. This technology provides a powerful yet flexible tool in the neurosurgical operating room.
引用
收藏
页码:510 / 514
页数:5
相关论文
共 11 条
  • [1] A FRAMELESS STEREOTAXIC OPERATING MICROSCOPE FOR NEUROSURGERY
    FRIETS, EM
    STROHBEHN, JW
    HATCH, JF
    ROBERTS, DW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (06) : 608 - 617
  • [2] GALLOWAY R L JR, 1991, Biomedical Instrumentation and Technology, V25, P457
  • [3] GUTHRIE BL, 1991, PERSPECT NEUROL SURG, V2, P1
  • [4] VOLUMETRIC STEREOTACTIC SURGICAL RESECTION OF INTRA-AXIAL BRAIN MASS LESIONS
    KELLY, PJ
    [J]. MAYO CLINIC PROCEEDINGS, 1988, 63 (12) : 1186 - 1198
  • [5] RESULTS OF COMPUTED TOMOGRAPHY-BASED COMPUTER-ASSISTED STEREOTACTIC RESECTION OF METASTATIC INTRACRANIAL TUMORS
    KELLY, PJ
    KALL, BA
    GOERSS, SJ
    [J]. NEUROSURGERY, 1988, 22 (01) : 7 - 17
  • [6] A ROBOT WITH IMPROVED ABSOLUTE POSITIONING ACCURACY FOR CT GUIDED STEREOTACTIC BRAIN SURGERY
    KWOH, YS
    HOU, J
    JONCKHEERE, EA
    HAYATI, S
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (02) : 153 - 160
  • [7] STEREOTACTIC CRANIOTOMY - METHODS AND RESULTS USING THE BROWN-ROBERTS-WELLS STEREOTACTIC FRAME
    MOORE, MR
    BLACK, PM
    ELLENBOGEN, R
    GALL, CM
    ELDREDGE, E
    [J]. NEUROSURGERY, 1989, 25 (04) : 572 - 578
  • [8] A FRAMELESS STEREOTAXIC INTEGRATION OF COMPUTERIZED TOMOGRAPHIC IMAGING AND THE OPERATING MICROSCOPE
    ROBERTS, DW
    STROHBEHN, JW
    HATCH, JF
    MURRAY, W
    KETTENBERGER, H
    [J]. JOURNAL OF NEUROSURGERY, 1986, 65 (04) : 545 - 549
  • [9] STERN WE, 1982, NEUROLOGICAL SURG, P1051
  • [10] 3-DIMENSIONAL DIGITIZER (NEURONAVIGATOR) - NEW EQUIPMENT FOR COMPUTED TOMOGRAPHY-GUIDED STEREOTAXIC SURGERY
    WATANABE, E
    WATANABE, T
    MANAKA, S
    MAYANAGI, Y
    TAKAKURA, K
    [J]. SURGICAL NEUROLOGY, 1987, 27 (06): : 543 - 547