Prognostic impact of average iodine density assessed by dual-energy spectral imaging for predicting lung tumor recurrence after stereotactic body radiotherapy

被引:45
作者
Aoki, Masahiko [1 ]
Hirose, Katsumi [2 ]
Sato, Mariko [1 ]
Akimoto, Hiroyoshi [1 ]
Kawaguchi, Hideo [1 ]
Hatayama, Yoshiomi [1 ]
Fujioka, Ichitaro [1 ]
Tanaka, Mitsuki [1 ]
Ono, Shuichi [1 ]
Takai, Yoshihiro [1 ]
机构
[1] Hirosaki Univ, Grad Sch Med, Dept Radiol & Radiat Oncol, 5 Zaifu Cho, Hirosaki, Aomori 0368562, Japan
[2] Southern Tohoku Proton Therapy Ctr, Dept Radiat Oncol, 7-172 Yatsuyamada, Koriyama, Fukushima 9638052, Japan
基金
日本学术振兴会;
关键词
dual-energy CT; iodine density; lung cancer; oligometastases; stereotactic body radiotherapy; CONTRAST ENHANCEMENT; MICROVESSEL DENSITY; CT; CANCER; TOMOGRAPHY; SIZE;
D O I
10.1093/jrr/rrv100
中图分类号
Q [生物科学];
学科分类号
090105 [作物生产系统与生态工程];
摘要
The purpose of this study was to investigate the prognostic significance of average iodine density as assessed by dual-energy computed tomography (DE-CT) for lung tumors treated with stereotactic body radiotherapy (SBRT). From March 2011 to August 2014, 93 medically inoperable patients with 74 primary lung cancers and 19 lung metastases underwent DE-CT prior to SBRT of a total dose of 45-60 Gy in 5-10 fractions. Of these 93 patients, nine patients had two lung tumors. Thus, 102 lung tumors were included in this study. DE-CT was performed for pretreatment evaluation. Regions of interest were set for the entire tumor, and average iodine density was obtained using a dedicated imaging software and evaluated with regard to local control. The median follow-up period was 23.4 months (range, 1.5-54.5 months). The median value of the average iodine density was 1.86 mg/cm(3) (range, 0.40-9.27 mg/cm(3)). Two-year local control rates for the high and low average iodine density groups divided by the median value of the average iodine density were 96.9% and 75.7% (P = 0.006), respectively. Tumors with lower average iodine density showed a worse prognosis, possibly reflecting a hypoxic cell population in the tumor. The average iodine density exhibited a significant impact on local control. Our preliminary results indicate that iodine density evaluated using dual-energy spectral CT may be a useful, noninvasive and quantitative assessment of radio-resistance caused by presumably hypoxic cell populations in tumors.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 26 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging [J].
Aoki, Masahiko ;
Takai, Yoshihiro ;
Narita, Yuichiro ;
Hirose, Katsumi ;
Sato, Mariko ;
Akimoto, Hiroyoshi ;
Kawaguchi, Hideo ;
Hatayama, Yoshiomi ;
Miura, Hiroyuki ;
Ono, Shuichi .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) :917-923
[3]
Clinical outcome of stereotactic body radiotherapy of 54 Gy in nine fractions for patients with localized lung tumor using a custom-made immobilization system [J].
Aoki M. ;
Abe Y. ;
Kondo H. ;
Hatayama Y. ;
Kawaguchi H. ;
Fujimori A. ;
Suzaki K. ;
Seino M. ;
Morita T. ;
Souma M. ;
Tsushima T. ;
Takanashi S. .
Radiation Medicine, 2007, 25 (6) :289-294
[4]
Head and Neck Squamous Cell Carcinoma: CT Perfusion Can Help Noninvasively Predict Intratumoral Microvessel Density [J].
Ash, Lorraine ;
Teknos, Theodoros N. ;
Gandhi, Dheerhaj ;
Patel, Samip ;
Mukherji, Suresh K. .
RADIOLOGY, 2009, 251 (02) :422-428
[5]
Clinical outcomes of stereotactic body radiotherapy for stage I non-small cell lung cancer using different doses depending on tumor size [J].
Baba, Fumiya ;
Shibamoto, Yuta ;
Ogino, Hiroyuki ;
Murata, Rumi ;
Sugie, Chikao ;
Iwata, Hiromitsu ;
Otsuka, Shinya ;
Kosaki, Katsura ;
Nagai, Aiko ;
Murai, Taro ;
Miyakawa, Akifumi .
RADIATION ONCOLOGY, 2010, 5
[6]
PROSPECTIVE, RISK-ADAPTED STRATEGY OF STEREOTACTIC BODY RADIOTHERAPY FOR EARLY-STAGE NON-SMALL-CELL LUNG CANCER: RESULTS OF A PHASE II TRIAL [J].
Bral, Samuel ;
Gevaert, Thierry ;
Linthout, Nadine ;
Versmessen, Harijati ;
Collen, Christine ;
Engels, Benedikt ;
Verdries, Douwe ;
Everaert, Hendrik ;
Christian, Nicolas ;
De Ridder, Mark ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1343-1349
[7]
Systemic review of the patterns of failure following stereotactic body radiation therapy in early-stage non-small-cell lung cancer: Clinical implications [J].
Chi, Alexander ;
Liao, Zhongxing ;
Nguyen, Nam P. ;
Xu, Jiahong ;
Stea, Baldassarre ;
Komaki, Ritsuko .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (01) :1-11
[8]
Dual-Energy CT: Oncologic Applications [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Bellini, Davide ;
Ayuso, Carmen ;
Laghi, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S98-S105
[9]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[10]
A challenge to traditional radiation oncology [J].
Fowler, JF ;
Tomé, WA ;
Fenwick, JD ;
Mehta, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1241-1256