共 16 条
A Randomized Trial Comparing Ceramic-on-Ceramic Bearing vs Ceramic-on-Crossfire-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
被引:23
作者:
Beaupre, Lauren A.
[1
,2
]
Al-Houkail, Amro
[2
]
Johnston, Donald William C.
[2
]
机构:
[1] Univ Alberta, Dept Phys Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4, Canada
[2] Univ Alberta, Div Orthopaed Surg, Dept Surg, Edmonton, AB T6G 2G4, Canada
基金:
加拿大健康研究院;
关键词:
total hip arthroplasty;
revision;
bearing surfaces;
health-related quality of life;
function;
FOLLOW-UP;
NO DIFFERENCES;
OUTCOMES;
MINIMUM;
SURVIVORSHIP;
METAANALYSIS;
D O I:
10.1016/j.arth.2015.11.043
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
100224 [整形外科学];
摘要:
Background: Bearing surfaces in total hip arthroplasty (THA) may affect implant longevity and hence patient outcomes. This randomized clinical trial determined how ceramic-on-ceramic (CERAMIC) bearing THA affected joint-specific pain, function, and stiffness and prosthesis fixation/longevity over 10 postoperative years compared with ceramic-on-highly-crosslinked-polyethylene (POLYETHYLENE) bearing THA. This is a follow-up to previously reported 5-year outcomes. Methods: Subjects aged <61 years were randomized to CERAMIC (n = 48) or POLYETHYLENE (n = 44) THA. Subjects were assessed using the Western Ontario McMaster Osteoarthritis Index and the RAND 12-Item Health Survey preoperatively, and at 1, 5, and 10 years postoperatively. Plain radiographs were evaluated at 10 years for fixation, and medical records were reviewed for revisions. Results: Of 92 subjects, 6 (7%) died within 10 years; 68 (79%) survivors provided radiographic and/or clinical follow-up at 10 years postoperatively. Improvements seen at 5 years in both the Western Ontario McMaster Osteoarthritis Index and RAND 12-Item Health Survey were retained at 10 years with no group differences (P > .48). There were no failures or loss of fixation related to bearing surfaces/wear in either group. Over 10 years, 3 subjects in the POLYETHYLENE group had revisions that were related to recurrent dislocation; 2 revisions were performed within 2 years of surgery, and one further subject underwent revision at 7 years postoperatively. Conclusions: This is one of the first randomized clinical trials to examine 10-year outcomes between CERAMIC and POLYETHYLENE bearing THAs. Both bearing surfaces performed well out to 10 years in subjects who were <61 years at time of surgery. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1240 / 1245
页数:6
相关论文