The energy savings potential of using dynamic external louvers in an office building

被引:153
作者
Hammad, Fawwaz [2 ]
Abu-Hijleh, Bassam [1 ]
机构
[1] British Univ Dubai, Atkins Chair, Fac Engn, Dubai, U Arab Emirates
[2] WS Atkins, Abu Dhabi, U Arab Emirates
关键词
Dynamic facades; Energy saving; Lighting control; UAE; Computer simulation; CONSUMPTION; PERFORMANCE; SYSTEM; BLINDS;
D O I
10.1016/j.enbuild.2010.05.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research is aimed at exploring the influence of external dynamic louvers on the energy consumption of an office building located in Abu Dhabi-UAE. The IES-VR software was used to predict the energy consumption of a representative office module in order to evaluate the overall energy performance of employing external louvers on the south, east and west oriented facades. The use of dynamic facades was compared to another simpler method of using light-sensor controlled light dimmers. The results show that the potential energy savings using light dimming strategy only was 24.4%, 24.45% and 25.19% for the south, east and west oriented facades, respectively. The proposed dynamic louvers system with light dimming strategy achieved energy savings of 34.02%, 28.57% and 30.31% for the south, east and west orientations, respectively. Detailed analysis of the results showed that the facade's optimal static angle was -20 degrees for the south oriented facade and 20 degrees for the east and west oriented facades. Using these fixed optimal angles resulted in slightly lower energy savings than that of the dynamic facades. This would seem to be a good tradeoff between savings in energy running cost and the investment required to install, operate and maintain a dynamic facades system. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1888 / 1895
页数:8
相关论文
共 27 条
[1]   A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device [J].
Athienitis, AK ;
Tzempelikos, A .
SOLAR ENERGY, 2002, 72 (04) :271-281
[2]  
Attia S., 2009, P BUILDING SIMULATIO, P204, DOI DOI 10.1016/J.BUILDENV.2006.10.027
[3]  
Block J., 2000, IESNA Lighting Handbook
[4]  
Carbonari A., 2002, Environmental Management and Health, V13, P392, DOI DOI 10.1108/09566160210439305
[5]  
Carpi A., 2008, POS, V1
[6]   THE EFFECT OF SLAT ANGLE OF WINDOWS WITH VENETIAN BLINDS ON HEATING AND COOLING LOADS OF BUILDINGS IN SOUTH-KOREA [J].
CHO, SH ;
SHIN, KS ;
ZAHEERUDDIN, M .
ENERGY, 1995, 20 (12) :1225-1236
[7]  
Ghiaus C., 2004, A Handbook for Intelligent Building, P26
[8]   An innovative lighting controller integrated in a self-adaptive building control system [J].
Guillemin, A ;
Morel, N .
ENERGY AND BUILDINGS, 2001, 33 (05) :477-487
[9]  
HARRISON A, 1997, INTELLIGENT BUILDING
[10]  
*INT ENV SOL LTD, 2009, IES VE US GUID VER 5