Seamless signal transduction from live cells to an NO sensor via a cell-adhesive sensing matrix

被引:28
作者
Asakawa, Hitoshi [1 ]
Mochitate, Katsumi [2 ]
Haruyama, Tetsuya [1 ]
机构
[1] Kyushu Inst Technol, Dept Biol Funct & Engn, Fukuoka 8080196, Japan
[2] Natl Inst Environm Studies, Tsukuba, Ibaraki 3058506, Japan
关键词
D O I
10.1021/ac702001u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A smart live-cell assay was developed as a cellular biosensing system. This system is based on novel tactics: the direct assembly of human cultured cells onto a cell-adhesive sensing matrix. This novel design provides considerable advantages, among them the possibility of capturing molecular signals immediately after they are secreted from living cells. The design also helps preserve all cellular characteristics intact. In this study, a cell-adhesive NO sensing matrix, acting as both an NO-permeable membrane and a cell-adhesive scaffold, was designed using functional polymers and a short peptide sequence derived from extracellular matrix (ECM) proteins. Using the cell-adhesive NO sensing matrix, we constructed a cellular biosensing system based on in situ monitoring of NO released from a human umbilical vein endothelial cell (HUVEC) layer. HUVECs were employed as an organ-functional model of a blood vessel in view of screening vasodilatory substances for clinical purposes. In our novel system, the electrochemical NO sensor is adjacent to the NO-producing cells, which allows the sensing device to achieve superior sensitivity and precise response to a very low number of NO molecules. Our design enables the fixing of the exact distance between the organ-functional model and the chemical sensor without cumbersome manipulations. Consequently, this cellular biosensing system may be readily applicable to high-throughput analysis in the field of drug screening.
引用
收藏
页码:1505 / 1511
页数:7
相关论文
共 26 条
  • [21] Detection and imaging of nitric oxide with novel fluorescent indicators: Diaminofluoresceins
    Kojima, H
    Nakatsubo, N
    Kikuchi, K
    Kawahara, S
    Kirino, Y
    Nagoshi, H
    Hirata, Y
    Nagano, T
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (13) : 2446 - 2453
  • [22] SELECTIVE AND SENSITIVE ELECTROCHEMICAL MEASUREMENT OF NITRIC-OXIDE IN AQUEOUS-SOLUTION - DISCUSSION AND NEW RESULTS
    LANTOINE, F
    TREVIN, S
    BEDIOUI, F
    DEVYNCK, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 392 (1-2): : 85 - 89
  • [23] Identification of biologically active sequences in the laminin α4 chain G domain
    Okazaki, I
    Suzuki, N
    Nishi, N
    Utani, A
    Matsuura, H
    Shinkai, H
    Yamashita, H
    Kitagawa, Y
    Nomizu, M
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2002, 277 (40) : 37070 - 37078
  • [24] Cyclic-nucleotide-gated channels mediate synaptic feedback by nitric oxide
    Savchenko, A
    Barnes, S
    Kramer, RH
    [J]. NATURE, 1997, 390 (6661) : 694 - 698
  • [25] Nitric oxide measurements in biological samples
    Taha, ZH
    [J]. TALANTA, 2003, 61 (01) : 3 - 10
  • [26] Walch L, 2001, THERAPIE, V56, P223