Initial evaluation of quantitative performance of chromatographic methods using replicates at multiple concentrations

被引:24
作者
Castillo, MA
Castells, RC
机构
[1] Natl Univ La Plata, Fac Ciencias Exactas, Div Quim Analit, RA-1900 La Plata, Argentina
[2] CIDEPINT, RA-1900 La Plata, Argentina
关键词
performance characteristics; repeatability; linearity; limit of detection; limit of quantitation; biogenic amines;
D O I
10.1016/S0021-9673(01)00867-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The introduction of a novel analytical method must be supported by consistent information about its quantitative potentialities; this is critical for whoever considers its utilization for an specific application. Unfortunately, Literature abounds in papers proposing excellent chromatographic methods of analysis that have been subjected to comparatively poor quantitative evaluation. The methodology proposed in the present work makes use of some of the performance characteristics whose measurement is recommended in validation protocols; pertinent to this stage of method development are the detection and quantitation limits, the linear range and the repeatability. All this information can be calculated from the results of a calibration with several replicates at each analyte level. Replicates enable the calculation of reproducibility at several. analyte levels and the estimation of the linear range; more important, replicates are necessary to detect changes in peak area standard deviation with analyte amount Regression of calibration data by means of unweighted least-squares (ULSR) can only be performed in those cases in which homoscedasticity has been previously verified; heteroscedastic calibration data demand regression by means of weighted least-squares (WLSR), since ULSR results in,gross overestimation of prediction limits at low analyte concentration. The proposal is used for the preliminary quantitative evaluation of a method for the determination of nine biogenic amines by means of pre-column derivatization with dabsyl chloride and separation of derivatives by RPLC. Limits of detection are calculated by a regression approach and by the classical signal-to-noise ratio method (SIN approach). No significant difference was detected for the amines limits of detection estimated by WLSR and by the SIN approach; ULSR estimated limits of detection are between 7 and 78 times larger than those obtained by the other two methods, as a consequence of the heteroscedasticity of calibration data. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 133
页数:13
相关论文
共 27 条
[1]  
[Anonymous], 1990, DETECTION ORIENTED D
[2]   Realistic detection limits from confidence bands [J].
Burdge, JR ;
MacTaggart, DL ;
Farwell, SO .
JOURNAL OF CHEMICAL EDUCATION, 1999, 76 (03) :434-439
[3]   NOMENCLATURE FOR THE PRESENTATION OF RESULTS OF CHEMICAL-ANALYSIS [J].
CURRIE, LA ;
SVEHLA, G .
PURE AND APPLIED CHEMISTRY, 1994, 66 (03) :595-608
[5]   Detection and quantification limits: origins and historical overview [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :127-134
[6]   NOMENCLATURE IN EVALUATION OF ANALYTICAL METHODS INCLUDING DETECTION AND QUANTIFICATION CAPABILITIES (IUPAC RECOMMENDATIONS 1995) [J].
CURRIE, LA .
PURE AND APPLIED CHEMISTRY, 1995, 67 (10) :1699-1723
[7]  
Draper N. R., 1966, APPL REGRESSION ANAL
[8]   NON-CONSTANT VARIANCE REGRESSION TECHNIQUES FOR CALIBRATION-CURVE-BASED ANALYSIS [J].
GARDEN, JS ;
MITCHELL, DG ;
MILLS, WN .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2310-2315
[9]  
*GERM NORM I, 1994, 32645 DIN
[10]  
Hinshaw JV, 2000, LC GC N AM, V18, P126