Preservation of the first rocker is related to increases in gait speed in individuals with hemiplegia and AFO

被引:48
作者
Nolan, Karen J. [1 ,2 ]
Yarossi, Mathew [1 ]
机构
[1] Kessler Fdn Res Ctr, Human Performance & Movement Anal Lab, W Orange, NJ USA
[2] Univ Med & Dent New Jersey, New Jersey Med Sch, Dept Phys Med & Rehabil, Newark, NJ 07103 USA
关键词
Hemiplegic gait; Impulse; Stroke; Ankle foot orthosis; Gait speed; ANKLE-FOOT ORTHOSIS; WALKING; STROKE; REHABILITATION; MOBILITY;
D O I
10.1016/j.clinbiomech.2011.03.011
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Changes in impulse during the first rocker (braking force) and third rocker (propulsion force) may affect changes in gait speed after orthotic intervention. The purpose of this investigation was to objectively measure changes in impulse during double support and correlate those findings to changes in gait speed with and without ankle foot orthosis in individuals with hemiplegia. Methods: Fifteen adults with stroke-related hemiplegia walked with and without ankle foot orthosis while foot pressure data was collected bilaterally. Outcome measures included: gait cycle time (s), mean force (N), and impulse (Ns) in the wholefoot, hindfoot, forefoot, and toe box during initial double support and terminal double support. Findings: Time significantly decreased during the entire gait cycle, initial double support, and terminal double support, with the ankle foot orthosis. During initial double support, affected limb impulse significantly decreased with the ankle foot orthosis in the wholefoot (P=0.016), and hindfoot (P=0.006), and hindfoot impulse % change and gait speed % change were significantly correlated (P=0.007). During terminal double support, affected limb impulse was not significantly different in the wholefoot or forefoot and these changes were not significantly correlated to gait speed. Interpretation: Previous research found that orthotics increase gait speed in individuals with hemiplegia. This research suggests that the increase in speed is not due to increased propulsive forces at the end of terminal double support, but due to decreased braking forces during initial double support. Therefore, the orthosis preserved the first ankle rocker and provided a more efficient weight acceptance which positively affected gait speed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 24 条
[1]
A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform (vol 15, pg 781, 2000) [J].
Barnett, S ;
Cunningham, JL ;
West, SE .
CLINICAL BIOMECHANICS, 2001, 16 (04) :351-+
[2]
Blessey R L, 1976, Phys Ther, V56, P1019
[3]
REHABILITATION GOALS OF PATIENTS WITH HEMIPLEGIA [J].
BOHANNON, RW ;
ANDREWS, AW ;
SMITH, MB .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1988, 11 (02) :181-183
[4]
Anterior-posterior ground reaction forces as a measure of paretic leg contribution in hemiparetic walking [J].
Bowden, MG ;
Balasubramanian, CK ;
Neptune, RR ;
Kautz, SA .
STROKE, 2006, 37 (03) :872-876
[5]
How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study [J].
Desloovere, Kaat ;
Molenaers, Guy ;
Van Gestel, Leen ;
Huenaerts, Catherine ;
Van Campenhout, Anja ;
Callewaert, Barbara ;
Van de Walle, Patricia ;
Seyler, J. .
GAIT & POSTURE, 2006, 24 (02) :142-151
[6]
Effect of ankle-foot orthosis on roll-over shape in adults with hemiplegia [J].
Fatone, Stefania ;
Hansen, Andrew H. .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2007, 44 (01) :11-20
[7]
Giuliani CA, 1990, GAIT REHABILITATION
[8]
Maximum voluntary weight-bearing by the affected and unaffected legs in standing following stroke [J].
Goldie, PA ;
Matyas, TA ;
Evans, OM ;
Galea, M ;
Bach, TM .
CLINICAL BIOMECHANICS, 1996, 11 (06) :333-342
[9]
Mobility assistive device utilization in a prospective study of patients with first-ever stroke [J].
Jutai, Jeffrey ;
Coulson, Sherry ;
Teasell, Robert ;
Bayley, Mark ;
Garland, Jayne ;
Mayo, Nancy ;
Wood-Dauphinee, Sharon .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (10) :1268-1275
[10]
Reliability of an in-shoe pressure measurement system during treadmill walking [J].
Kernozek, TW ;
LaMott, EE ;
Dancisak, MJ .
FOOT & ANKLE INTERNATIONAL, 1996, 17 (04) :204-209