Functionally graded hydroxyapatite coatings doped with antibacterial components

被引:135
作者
Bai, Xiao [1 ]
More, Karren [2 ]
Rouleau, Christopher M. [3 ]
Rabiei, Afsaneh [1 ]
机构
[1] N Carolina State Univ, Raleigh, NC 27695 USA
[2] Oak Ridge Natl Lab, Div Mat Sci & Technol, Oak Ridge, TN 37831 USA
[3] Oak Ridge Natl Lab, Ctr Nanophase Mat Sci, Oak Ridge, TN 37831 USA
基金
美国国家科学基金会;
关键词
Ion beam processing; Hydroxyapatite coating; Adhesion strength; Antimicrobial; CALCIUM-PHOSPHATE COATINGS; BEAM-ASSISTED DEPOSITION; MECHANICAL-PROPERTIES; SUBSTITUTED HYDROXYAPATITE; SILVER; MICROSTRUCTURE; IONS; CYTOTOXICITY; SUBSTRATE; FILMS;
D O I
10.1016/j.actbio.2009.12.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A series of functionally graded hydroxyapatite (FGHA) coatings incorporated with various percentages of silver were deposited on titanium substrates using ion beam-assisted deposition. The analysis of the coating's cross-section using transmission electron microscopy (TEM) and scanning transmission electron microscopy equipped with energy dispersive X-ray spectroscopy has shown a decreased crystallinity as well as a distribution of nanoscale (10-50 nm) silver particles from the coating/substrate interface to top surface. Both X-ray diffraction and fast Fourier transforms on high-resolution TEM images revealed the presence of hydroxyapatite within the coatings. The amount of Ag (wt.%) on the outer surface of the FGHA, as determined from X-ray photoelectron spectroscopy, ranged from 1.09 to 6.59, which was about half of the average Ag wt.% incorporated in the entire coating. Average adhesion strengths evaluated by pull-off tests were in the range of 83 +/- 6 to 88 +/- 3 MPa, which is comparable to 85 MPa for FGHA without silver. Further optical observations of failed areas illustrated that the dominant failure mechanism was epoxy failure, and FGHA coating delamination was not observed. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2264 / 2273
页数:10
相关论文
共 45 条
[11]   Anti-microbial hydroxyapatite particles synthesized by a sol-gel route [J].
Chung, RJ ;
Hsieh, MF ;
Huang, KC ;
Perng, LH ;
Chou, FI ;
Chin, TS .
JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2005, 33 (02) :229-239
[12]   Thermal residual stresses near the interface between plasma-sprayed hydroxyapatite coating and titanium substrate: Finite element analysis and synchrotron radiation measurements [J].
Cofino, B ;
Fogarassy, P ;
Millet, P ;
Lodini, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 70A (01) :20-27
[13]  
Ding SJ, 1999, J BIOMED MATER RES, V44, P266, DOI 10.1002/(SICI)1097-4636(19990305)44:3<266::AID-JBM5>3.0.CO
[14]  
2-4
[15]   Antibacterial effects of Ag-HAp thin films on alumina substrates [J].
Feng, QL ;
Kim, TN ;
Wu, J ;
Park, ES ;
Kim, JO ;
Lim, DY ;
Cui, FZ .
THIN SOLID FILMS, 1998, 335 (1-2) :214-219
[16]  
Feng QL, 2000, J BIOMED MATER RES, V52, P662, DOI 10.1002/1097-4636(20001215)52:4<662::AID-JBM10>3.0.CO
[17]  
2-3
[18]   Ag-substituted hydroxyapatite coatings with both antimicrobial effects and biocompatibility [J].
Feng, QL ;
Cui, FZ ;
Kim, TN ;
Kim, JW .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1999, 18 (07) :559-561
[19]   Processing and in vitro behavior of hydroxyapatite coatings prepared by electrostatic spray assisted vapor deposition method [J].
Hou, Xianghui ;
Choy, Kwang-Leong ;
Leach, Sian Ellen .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 83A (03) :683-691
[20]   Definition of silver concentration in calcium phosphate coatings on titanium implants ensuring balancing of bactericidity and cytotoxicity [J].
Karlov, AV ;
Shakhov, VP ;
Kolobov, JR .
BIOCERAMICS, 2000, 192-1 :207-209