Measurement of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and human urine by high performance liquid chromatography-electrospray tandem mass spectrometry

被引:98
作者
Weimann, A [1 ]
Belling, D [1 ]
Poulsen, HE [1 ]
机构
[1] Rigshosp, Dept Clin Pharmacol, DK-2100 Copenhagen O, Denmark
关键词
8-oxo-2 '-deoxyguanosine; 8-oxo-2 '-deoxyadenosine; oxidative stress; nucleosides; electrospray; isotope dilution; free radicals;
D O I
10.1016/S0891-5849(01)00462-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method for the determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and urine by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometry is described. For the urine samples there is no sample preparation except for addition of buffer and internal standards followed by redissolvation of precipitate containing 8-oxo-2'-deoxyguanosine and a centrifugation step before the samples are injected onto the HPLC column. The detection Limit for 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine is approximately 0.3 nM corresponding to 7.5 fmol injected. Long runs, that is, > 50 samples, can be analyzed with only minimal loss of sensitivity. The concentrations excreted into urine samples from humans are between 1 and 100 nM for 8-oxo-2'-deoxyguanosine and below 0.3 nM for 8-oxo-2'-deoxyadenosine. In calf thymus DNA levels down to about 1 oxidized guanosine and adenosine per 10(6) unmodified bases can be detected. High levels of 8-oxo-2'-deoxyguanosine were found, 30 per 10(6) 2'-deoxyguanosine, levels of 8-oxo-2'-deoxyadenosine are at or below the detection limit. These findings indicate that High Performance Liquid Chromatography-Tandem Mass Spectrometry is a highly sensitive and specific method for analysis of oxidative DNA modifications in tissue as well as for analysis of excretion of oxidized nucleotides into urine that ensures a minimum artifact formation. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:757 / 764
页数:8
相关论文
共 47 条
[21]   A THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY METHOD FOR ANALYSIS OF HUMAN URINE FOR THE MAJOR MALONDIALDEHYDE GUANINE ADDUCT [J].
JAJOO, HK ;
BURCHAM, PC ;
GODA, Y ;
BLAIR, IA ;
MARNETT, LJ .
CHEMICAL RESEARCH IN TOXICOLOGY, 1992, 5 (06) :870-875
[22]   Repair of products of oxidative DNA base damage in human cells [J].
Jaruga, P ;
Dizdaroglu, M .
NUCLEIC ACIDS RESEARCH, 1996, 24 (08) :1389-1394
[23]   Measurement of oxidative DNA damage by gas chromatography mass spectrometry: ethanethiol prevents artifactual generation of oxidized DNA bases [J].
Jenner, A ;
England, TG ;
Aruoma, OI ;
Halliwell, B .
BIOCHEMICAL JOURNAL, 1998, 331 :365-369
[24]   FORMATION OF 8-HYDROXYGUANINE MOIETY IN CELLULAR DNA BY AGENTS PRODUCING OXYGEN RADICALS AND EVIDENCE FOR ITS REPAIR [J].
KASAI, H ;
CRAIN, PF ;
KUCHINO, Y ;
NISHIMURA, S ;
OOTSUYAMA, A ;
TANOOKA, H .
CARCINOGENESIS, 1986, 7 (11) :1849-1851
[25]   High-performance liquid chromatography electrospray mass spectrometry for the analysis of modified bases in DNA: 7-(2-hydroxyethyl)guanine, the major ethylene oxide DNA adduct [J].
Leclercq, L ;
Laurent, C ;
DePauw, E .
ANALYTICAL CHEMISTRY, 1997, 69 (10) :1952-1955
[26]  
Liu PK, 1996, J NEUROSCI, V16, P6795
[27]   OXIDATIVE DNA DAMAGE ESTIMATED BY 8-HYDROXYDEOXYGUANOSINE EXCRETION IN HUMANS - INFLUENCE OF SMOKING, GENDER AND BODY-MASS INDEX [J].
LOFT, S ;
VISTISEN, K ;
EWERTZ, M ;
TJONNELAND, A ;
OVERVAD, K ;
POULSEN, HE .
CARCINOGENESIS, 1992, 13 (12) :2241-2247
[28]   Determination of 8-oxoguanine in human plasma and urine by high-performance liquid chromatography with electrochemical detection [J].
Long, LN ;
McCabe, DR ;
Dolan, ME .
JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02) :241-249
[29]   ESCODD: European Standards Committee on Oxidative DNA damage [J].
Lunec, J .
FREE RADICAL RESEARCH, 1998, 29 (06) :601-608
[30]   Determination of 8-hydroxy-2′-deoxyguanosine in urine by liquid chromatography-electrospray ionization-mass spectrometry [J].
Moriwaki, H .
ANALYTICAL SCIENCES, 2000, 16 (02) :105-106