Biological and Analytical Variations of 16 Parameters Related to Coagulation Screening Tests and the Activity of Coagulation Factors

被引:32
作者
Chen, Qian [1 ,2 ]
Shou, Weiling [1 ,2 ]
Wu, Wei [1 ,2 ]
Guo, Ye [1 ,2 ]
Zhang, Yujuan [1 ,2 ]
Huang, Chunmei [1 ,2 ]
Cui, Wei [1 ,2 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Clin Lab, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100730, Peoples R China
关键词
biological variation; coagulation parameters; index of individuality; reference change values; WITHIN-SUBJECT; ROUTINE; TEMPERATURE; VARIABILITY; HEMOSTASIS; QUALITY; VALUES; TIME;
D O I
10.1055/s-0034-1543994
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 27 条
[1]  
Awad Mohammed A, 2004, Hematology, V9, P333, DOI 10.1080/10245330400010646
[2]   Biological Variation in Tests of Hemostasis (vol 34, pg 635, 2008) [J].
Banfi, Giuseppe ;
Del Fabbro, Massimo .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2009, 35 (01) :119-126
[3]  
Chambless L E, 1992, Ann Epidemiol, V2, P723
[4]  
COSTONGS GMPJ, 1985, J CLIN CHEM CLIN BIO, V23, P7
[5]   WITHIN-SUBJECT AND BETWEEN-SUBJECT BIOLOGICAL VARIATION OF PROTHROMBIN TIME AND ACTIVATED PARTIAL THROMBOPLASTIN TIME [J].
DOT, D ;
MIRO, J ;
FUENTESARDERIU, X .
ANNALS OF CLINICAL BIOCHEMISTRY, 1992, 29 :422-425
[6]   Measuring the quality of journals and journal articles: The impact factor tells but a portion of the story [J].
Favaloro, Emmanuel J. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (01) :7-25
[7]   Aging Hemostasis: Changes to Laboratory Markers of Hemostasis As We Age-A Narrative Review [J].
Favaloro, Emmanuel J. ;
Franchini, Massimo ;
Lippi, Giuseppe .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2014, 40 (06) :621-633
[8]   Pre-analytical Variables in Coagulation Testing Associated With Diagnostic Errors in Hemostasis [J].
Favaloro, Emmanuel J. ;
Funk, Dorothy M. ;
Lippi, Giuseppe .
LABMEDICINE, 2012, 43 (02) :54-60
[9]   Reference change values [J].
Fraser, Callum G. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (05) :807-812
[10]   BIOLOGIC VARIATION OF COMMON HEMATOLOGIC LABORATORY QUANTITIES IN THE ELDERLY [J].
FRASER, CG ;
WILKINSON, SP ;
NEVILLE, RG ;
KNOX, JDE ;
KING, JF ;
MACWALTER, RS .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (04) :465-470