Biological and Analytical Variations of 16 Parameters Related to Coagulation Screening Tests and the Activity of Coagulation Factors

被引:32
作者
Chen, Qian [1 ,2 ]
Shou, Weiling [1 ,2 ]
Wu, Wei [1 ,2 ]
Guo, Ye [1 ,2 ]
Zhang, Yujuan [1 ,2 ]
Huang, Chunmei [1 ,2 ]
Cui, Wei [1 ,2 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Clin Lab, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100730, Peoples R China
关键词
biological variation; coagulation parameters; index of individuality; reference change values; WITHIN-SUBJECT; ROUTINE; TEMPERATURE; VARIABILITY; HEMOSTASIS; QUALITY; VALUES; TIME;
D O I
10.1055/s-0034-1543994
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 27 条
[21]   The reference change value:: a proposal to interpret laboratory reports in serial testing based on biological variation [J].
Ricós, C ;
Cava, F ;
García-Lario, JV ;
Hernández, A ;
Iglesias, N ;
Jiménez, CV ;
Minchinela, J ;
Perich, C ;
Simón, M ;
Domenech, MV ;
Alvarez, V .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2004, 64 (03) :175-184
[22]   Within-subject biological variation in disease:: collated data and clinical consequences [J].
Ricos, Carmen ;
Iglesias, Natalia ;
Garcia-Lario, Jose-Vicente ;
Simon, Margarita ;
Cava, Fernando ;
Hernandez, Amparo ;
Perich, Carmen ;
Minchinela, Joanna ;
Alvarez, Virtudes ;
Domenech, Maria-Vicenta ;
Jimenez, Carlos-Victor ;
Biosca, Carmen ;
Tena, Raquel .
ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 :343-352
[23]   INTRAINDIVIDUAL VARIABILITY OF FIBRINOGEN LEVELS AND CARDIOVASCULAR RISK PROFILE [J].
ROSENSON, RS ;
TANGNEY, CC ;
HAFNER, JM .
ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (12) :1928-1932
[24]   Influence of temperature and time before centrifugation of specimens for routine coagulation testing [J].
Salvagno, G. L. ;
Lippi, G. ;
Montagnana, M. ;
Franchini, M. ;
Poli, G. ;
Guidi, G. C. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2009, 31 (04) :462-467
[25]  
Siegel JE, 1998, AM J CLIN PATHOL, V110, P106
[26]  
THOMPSON SG, 1987, THROMB HAEMOSTASIS, V58, P1073
[27]   Preanalytical variables and off-site blood collection: Influences on the results of the prothrombin time/International Normalized Ratio test and implications for monitoring of oral anticoagulant therapy [J].
van Geest-Daalderop, JHH ;
Mulder, AB ;
Boonman-de Winter, LJM ;
Hoekstra, MMCL ;
van den Besselaar, AMHP .
CLINICAL CHEMISTRY, 2005, 51 (03) :561-568